Your browser doesn't support javascript.
loading
Real-time contact force sensing for pulmonary vein isolation in the setting of paroxysmal atrial fibrillation: procedural and 1-year results.
Marijon, Eloi; Fazaa, Samia; Narayanan, Kumar; Guy-Moyat, Benoit; Bouzeman, Abdeslam; Providencia, Rui; Treguer, Frederic; Combes, Nicolas; Bortone, Agustin; Boveda, Serge; Combes, Stephane; Albenque, Jean-Paul.
Afiliação
  • Marijon E; Clinique Pasteur, Département de Rythmologie, Toulouse, France; Paris Cardiovascular Research Center, Paris, France.
J Cardiovasc Electrophysiol ; 25(2): 130-7, 2014 Feb.
Article em En | MEDLINE | ID: mdl-24433324
ABSTRACT

INTRODUCTION:

The additional benefit of contact force (CF) technology during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (AF) to improve mid-term clinical outcome is unclear. METHODS AND

RESULTS:

Eligible patients with symptomatic paroxysmal AF were enrolled in this prospective trial, comparing circular antral catheter ablation (guided by Carto 3 System, Biosense Webster) using either a new open-irrigated CF catheter (SmartTouch Thermocool, Biosense Webster) (CF group) or a non-CF open-irrigated catheter (EZ Steer Thermocool, Biosense Webster) (control group). Overall, 30 patients were enrolled in each group, with a standardized 12-month follow-up, free of antiarrhythmic therapy. Demographic, cardiovascular and anatomic characteristics were similar in both groups. Though complete PVI was eventually achieved in all cases in both groups, success using an exclusive anatomic approach was 80.0% in CF group versus 36.7% in control group (P < 0.0001). CF use was associated with significant reductions in fluoroscopy exposure (P < 0.01) and radiofrequency time (P = 0.01). The incidence rates of AF recurrence were 10.5% (95% CI, 1.38-22.4) in the CF group, and 35.9% (95% CI, 12.4-59.4) in the control group (log rank test, P = 0.04). After adjustment on potential confounders, the use of CF catheter was found to be associated with a lower AF recurrence (OR 0.18, 95% CI 0.04-0.94, P = 0.04).

CONCLUSION:

Our findings suggest a potential benefit of real-time CF sensing technology, in reducing AF recurrence during the first year after PVI.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Ablação por Cateter / Cirurgia Assistida por Computador / Sistema de Condução Cardíaco Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Ablação por Cateter / Cirurgia Assistida por Computador / Sistema de Condução Cardíaco Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article