Your browser doesn't support javascript.
loading
Prompt detection of influenza A and B viruses using the BD Veritor™ System Flu A+B, Quidel® Sofia® Influenza A+B FIA, and Alere BinaxNOW® Influenza A&B compared to real-time reverse transcription-polymerase chain reaction (RT-PCR).
Dunn, Jim; Obuekwe, Joy; Baun, Traci; Rogers, Justin; Patel, Twinkle; Snow, Linda.
Afiliação
  • Dunn J; Department of Pathology and Laboratory Medicine, Cook Children's Medical Center, Fort Worth, TX 76104, USA. Electronic address: Jim.Dunn@cookchildrens.org.
  • Obuekwe J; Department of Pathology and Laboratory Medicine, Cook Children's Medical Center, Fort Worth, TX 76104, USA.
  • Baun T; Department of Pathology and Laboratory Medicine, Cook Children's Medical Center, Fort Worth, TX 76104, USA.
  • Rogers J; Department of Pathology and Laboratory Medicine, Cook Children's Medical Center, Fort Worth, TX 76104, USA.
  • Patel T; Department of Pathology and Laboratory Medicine, Cook Children's Medical Center, Fort Worth, TX 76104, USA.
  • Snow L; Department of Pathology and Laboratory Medicine, Cook Children's Medical Center, Fort Worth, TX 76104, USA.
Diagn Microbiol Infect Dis ; 79(1): 10-3, 2014 May.
Article em En | MEDLINE | ID: mdl-24582581
The performance characteristics of rapid influenza diagnostic tests vary widely. This study evaluated the BD Veritor™ System Flu A+B (Veritor; BD Diagnostics, Sparks, MD, USA), Quidel® Sofia® Influenza A+B FIA (Sofia; Quidel Corp., San Diego, CA, USA), and Alere BinaxNOW® Influenza A&B (Binax; Alere Scarborough, Inc., Scarborough, ME, USA) compared to reverse transcription-polymerase chain reaction (RT-PCR) for detection of influenza viruses in nasal wash specimens from 240 pediatric patients. Positive percent agreements for influenza A and B virus detection were 93.8% and 94.2%, 95.8% and 98.1%, and 79.2% and 80.8% for Veritor, Sofia, and Binax, respectively. The Veritor and Binax tests demonstrated negative percent agreements >97.9% for detection of both influenza viruses, but the negative percent agreement of the Sofia test was 91.1% for influenza A and 70.7% for influenza B virus. Overall, the Veritor and Sofia tests were nearly as sensitive as RT-PCR and considerably more sensitive than Binax for detection of influenza viruses. However, the accuracy of the Sofia test was significantly lower than either Veritor or Binax.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vírus da Influenza A / Vírus da Influenza B / Kit de Reagentes para Diagnóstico / Influenza Humana / Reação em Cadeia da Polimerase em Tempo Real Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vírus da Influenza A / Vírus da Influenza B / Kit de Reagentes para Diagnóstico / Influenza Humana / Reação em Cadeia da Polimerase em Tempo Real Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article