Your browser doesn't support javascript.
loading
Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme.
Timmermans, Lore; De Hauwere, An; Bacher, Klaus; Bosmans, Hilde; Lemmens, Kim; Bleyen, Luc; Van Limbergen, Erik; Martens, Patrick; Van Steen, Andre; Mortier, Griet; Van Herck, Koen; Thierens, Hubert.
Afiliação
  • Timmermans L; Department of Basic Medical Sciences, QCC-Gent, Ghent University, Ghent, Belgium, Lore.Timmermans@UGent.be.
Eur Radiol ; 24(8): 1808-19, 2014 Aug.
Article em En | MEDLINE | ID: mdl-24816932
ABSTRACT

OBJECTIVES:

To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM).

METHODS:

Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme.

RESULTS:

Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30% in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR.

CONCLUSIONS:

No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR. KEY POINTS • Performance parameters showed no major differences after digitalisation to CR or DR. • Transition from SFM to CR results in a higher mean glandular dose. • Transition from SFM to DR results in a lower mean glandular dose.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Mamografia / Intensificação de Imagem Radiográfica / Avaliação de Programas e Projetos de Saúde / Programas de Rastreamento / Detecção Precoce de Câncer Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Aged / Female / Humans / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Mamografia / Intensificação de Imagem Radiográfica / Avaliação de Programas e Projetos de Saúde / Programas de Rastreamento / Detecção Precoce de Câncer Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Aged / Female / Humans / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2014 Tipo de documento: Article