Your browser doesn't support javascript.
loading
Use of oral gadobenate dimeglumine to visualise the oesophagus during magnetic resonance angiography in patients with atrial fibrillation prior to catheter ablation.
Faletti, Riccardo; Rapellino, Alessandro; Barisone, Francesca; Anselmino, Matteo; Ferraris, Federico; Fonio, Paolo; Gaita, Fiorenzo; Gandini, Giovanni.
Afiliação
  • Rapellino A; Istituto di Radiologia dell'Università degli Studi di Torino, A,O, Città della Salute e della Scienza, Via Genova 3, 10126 Torino, Italy. alessandro.rapellino@fastwebnet.it.
J Cardiovasc Magn Reson ; 16: 41, 2014 Jun 13.
Article em En | MEDLINE | ID: mdl-24927953
ABSTRACT

BACKGROUND:

Atrio-oesophageal fistula was first reported as a fatal complication of surgical endocardial and percutaneous endocardial radiofrequency ablation for atrial fibrillation, with an incidence after catheter ablation between 0.03% and 0.5%. Magnetic resonance angiography (MRA) was usually performed to obtain pre-procedural 3D images, used to merging into an electro-anatomical map, guiding step-by-step ablation strategy of AF. Our aim was to find an easy, safe and cost-effective way to enhance the oesophagus during MRA.

METHODS:

In 105 consecutive patients, a right-left phase encoding, free breathing, 3D T1 MRA sequence was performed in the axial plane, >24 hours before catheter ablation, using an intravenous injection of gadobenate dimeglumine contrast medium. The oesophagus was enhanced using an oral gel solution of 0.7 mL gadobenate dimeglumine contrast medium mixed with approximately 40 mg thickened water gel, which was swallowed by the patients on the scanning table, immediately before the MRA sequence acquisition.

RESULTS:

The visualisation of the oesophagus was obtained in 104/105 patients and images were successfully merged, as left atrium and pulmonary veins, into an electro-anatomical map, during percutaneous endocardial radiofrequency ablation. All patients tolerated the study protocol and no immediate or late complication was observed with the oral contrast agent administration. The free-breathing MRA sequence used in our protocol took 7 seconds longer than MRA breath-hold conventional sequence.

CONCLUSION:

Oesophagus visualization with oral gadobenate dimeglumine is feasible for integration of oesophagus anatomy images into the electro-anatomical map during AF ablation, without undesirable side effects and without significantly increasing cost or examination time.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Fibrilação Atrial / Ablação por Cateter / Angiografia por Ressonância Magnética / Meios de Contraste / Esôfago / Meglumina Tipo de estudo: Etiology_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Fibrilação Atrial / Ablação por Cateter / Angiografia por Ressonância Magnética / Meios de Contraste / Esôfago / Meglumina Tipo de estudo: Etiology_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article