Your browser doesn't support javascript.
loading
Pulmonary artery rupture in a patient receiving an orthotopic heart transplant after total artificial heart explant.
Middle East J Anaesthesiol ; 22(4): 433-6, 2014 Feb.
Article em En | MEDLINE | ID: mdl-25007699
Our case illustrates a patient who suffered a pulmonary artery rupture despite previous total artificial heart implantation and replacement with orthotopic heart transplant. Pulmonary artery rupture during or following cardiac surgery has been reported to occur due to both pulmonary artery catheter use and surgical technique. Our case is the first to demonstrate the occurrence of this complication in the total artificial heart patient population.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Artéria Pulmonar / Cateterismo de Swan-Ganz / Transplante de Coração / Coração Artificial / Ruptura Cardíaca Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article