Your browser doesn't support javascript.
loading
Anoxic gas recirculation system for fouling control in anoxic membrane reactor.
Lee, Hansaem; Lee, Daeju; Hong, Seongwan; Yun, Geum Hee; Kim, Sungpyo; Hwang, Jung Ki; Lee, Woojae; Yun, Zuwhan.
Afiliação
  • Lee H; Research Institute for Environmental Technology and Sustainable Development, Korea University, Seoul 136-713, Korea. Electronic address: lhs1351@korea.ac.kr.
  • Lee D; Department of Environmental Engineering, Korea University, Sejong 339-700, Korea.
  • Hong S; Department of Environmental Engineering, Korea University, Sejong 339-700, Korea.
  • Yun GH; Department of Environmental Engineering, Korea University, Sejong 339-700, Korea.
  • Kim S; Department of Environmental Engineering, Korea University, Sejong 339-700, Korea.
  • Hwang JK; Dongbu Corporation, Seoul 135-523, Korea.
  • Lee W; Dongbu Corporation, Seoul 135-523, Korea.
  • Yun Z; Department of Environmental Engineering, Korea University, Sejong 339-700, Korea. Electronic address: envzyun@korea.ac.kr.
J Environ Sci (China) ; 26(6): 1289-93, 2014 Jun 01.
Article em En | MEDLINE | ID: mdl-25079838
ABSTRACT
Anoxic gas recirculation system was applied to control the membrane fouling in pilot-scale 4-stage anoxic membrane bioreactor (MBR). In the anaerobic-anoxic-anoxic-aerobic flow scheme, hydrophilic polytetrafluoroethylene (PTFE) membrane (0.2 µm, 7.2 m(2)/module) was submerged in the second anoxic zone. During 8 months operation, the average flux of the membrane was 21.3 L/(m(2)·hr). Chemical cleaning of the membrane was conducted only once with sodium hydroxide and sodium hypochlorite. Dissolved oxygen (DO) concentration in the second anoxic zone was maintained with an average of 0.19 ± 0.05 mg/L. Gas chromatography analysis showed that the headspace gas in the second anoxic reactor was mainly consisted of N2 (93.0% ± 2.5%), O2 (3.8% ± 0.6%), and CO2 (3.0% ± 0.5%), where the saturation DO concentration in liquid phase was 1.57 mg/L. Atmospheric O2 content (20.5% ± 0.8%) was significantly reduced in the anoxic gas. The average pH in the reactor was 7.2 ± 0.4. As a result, the recirculation of the anoxic gas was successfully applied to control the membrane fouling in the anoxic MBR.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reatores Biológicos / Incrustação Biológica Tipo de estudo: Evaluation_studies Idioma: En Ano de publicação: 2014 Tipo de documento: Article