Your browser doesn't support javascript.
loading
Modeling and robust pooling design of a preparative cation-exchange chromatography step for purification of monoclonal antibody monomer from aggregates.
Borg, Niklas; Brodsky, Yan; Moscariello, John; Vunnum, Suresh; Vedantham, Ganesh; Westerberg, Karin; Nilsson, Bernt.
Afiliação
  • Borg N; Department of Chemical Engineering, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden.
  • Brodsky Y; Product and Process Development, Amgen, 1201 Amgen Court West, Seattle, WA 98119, United States.
  • Moscariello J; Product and Process Development, Amgen, 1201 Amgen Court West, Seattle, WA 98119, United States.
  • Vunnum S; Biosimilars, Amgen, One Amgen Center Drive, Thousand Oaks, CA 91320, United States.
  • Vedantham G; Product and Process Development, Amgen, 1201 Amgen Court West, Seattle, WA 98119, United States.
  • Westerberg K; Department of Chemical Engineering, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden.
  • Nilsson B; Department of Chemical Engineering, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden. Electronic address: bernt.nilsson@chemeng.lth.se.
J Chromatogr A ; 1359: 170-81, 2014 Sep 12.
Article em En | MEDLINE | ID: mdl-25085821
ABSTRACT
This study has implemented and calibrated a model that describes the separation of the monomer of monoclonal antibodies from the dimer and larger oligomers on preparative-scale using cation-exchange chromatography. A general rate model with temperature dependent diffusion was coupled to a pH- and temperature-dependent steric mass action model. The model was shown to predict the retention of the monomer, dimer, and oligomer at low loadings for different pH levels and temperatures. Additionally, the model was shown to adequately predict the elution behavior of the monomer and soluble aggregates at high loadings within the same ranges with some limitations. The model was not able to accurately describe the shape of the product break-through curves or the slight levels of co-elution of the dimer and oligomer with the monomer at higher pH. The model was used to predict how 12 process variations impact the separation. The model is used to establish an elution end collection criterion such that the step can robustly provide the target purity of monomers.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Resinas de Troca de Cátion / Cromatografia por Troca Iônica / Anticorpos Monoclonais Tipo de estudo: Evaluation_studies / Prognostic_studies Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Resinas de Troca de Cátion / Cromatografia por Troca Iônica / Anticorpos Monoclonais Tipo de estudo: Evaluation_studies / Prognostic_studies Idioma: En Ano de publicação: 2014 Tipo de documento: Article