Your browser doesn't support javascript.
loading
Accounting for photophysical processes and specific signal intensity changes in fluorescence-detected sedimentation velocity.
Zhao, Huaying; Ma, Jia; Ingaramo, Maria; Andrade, Eric; MacDonald, Jeff; Ramsay, Glen; Piszczek, Grzegorz; Patterson, George H; Schuck, Peter.
Afiliação
  • Zhao H; Dynamics of Macromolecular Assembly Section, Laboratory of Cellular Imaging and Macromolecular Biophysics, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health , Bethesda, Maryland 20892, United States.
Anal Chem ; 86(18): 9286-92, 2014 Sep 16.
Article em En | MEDLINE | ID: mdl-25136929
ABSTRACT
Fluorescence detected sedimentation velocity (FDS-SV) has emerged as a powerful technique for the study of high-affinity protein interactions, with hydrodynamic resolution exceeding that of diffusion-based techniques, and with sufficient sensitivity for binding studies at low picomolar concentrations. For the detailed quantitative analysis of the observed sedimentation boundaries, it is necessary to adjust the conventional sedimentation models to the FDS data structure. A key consideration is the change in the macromolecular fluorescence intensity during the course of the experiment, caused by slow drifts of the excitation laser power, and/or by photophysical processes. In the present work, we demonstrate that FDS-SV data have inherently a reference for the time-dependent macromolecular signal intensity, resting on a geometric link between radial boundary migration and plateau signal. We show how this new time-domain can be exploited to study molecules exhibiting photobleaching and photoactivation. This expands the application of FDS-SV to proteins tagged with photoswitchable fluorescent proteins, organic dyes, or nanoparticles, such as those recently introduced for subdiffraction microscopy and enables FDS-SV studies of their interactions and size distributions. At the same time, we find that conventional fluorophores undergo minimal photobleaching under standard illumination in the FDS. These findings support the application of a high laser power density for the detection, which we demonstrate can further increase the signal quality.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultracentrifugação / Proteínas Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultracentrifugação / Proteínas Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article