Your browser doesn't support javascript.
loading
A reusable magnetic graphene oxide-modified biosensor for vascular endothelial growth factor detection in cancer diagnosis.
Lin, Chih-Wen; Wei, Kuo-Chen; Liao, Shih-sheng; Huang, Chiung-Yin; Sun, Chia-Liang; Wu, Pei-Jung; Lu, Yu-Jen; Yang, Hung-Wei; Ma, Chen-Chi M.
Afiliação
  • Lin CW; Department of Chemical Engineering, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan, ROC.
  • Wei KC; Department of Neurosurgery, Chang Gung Memorial Hospital, Linkou, 5 Fu-shing Road, Kuei-Shan, Tao-Yuan 33305, Taiwan, ROC.
  • Liao SS; Department of Chemical Engineering, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan, ROC.
  • Huang CY; Department of Neurosurgery, Chang Gung Memorial Hospital, Linkou, 5 Fu-shing Road, Kuei-Shan, Tao-Yuan 33305, Taiwan, ROC.
  • Sun CL; Department of Chemical and Materials Engineering, Chang Gung University, 259 Wen-Hwa 1st Road, Kuei-Shan, Tao-Yuan 33302, Taiwan, ROC.
  • Wu PJ; Department of Chemical Engineering, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan, ROC.
  • Lu YJ; Department of Neurosurgery, Chang Gung Memorial Hospital, Linkou, 5 Fu-shing Road, Kuei-Shan, Tao-Yuan 33305, Taiwan, ROC.
  • Yang HW; Institute of Medical Science and Technology, National Sun Yat-sen University, Kaohsiung 80424, Taiwan, ROC. Electronic address: howardyang@mail.nsysu.edu.tw.
  • Ma CC; Department of Chemical Engineering, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan, ROC. Electronic address: ccma@che.nthu.edu.tw.
Biosens Bioelectron ; 67: 431-7, 2015 May 15.
Article em En | MEDLINE | ID: mdl-25223552
ABSTRACT
Early cancer diagnosis is critical for the prevention of metastasis. However, simple and efficient methods are needed to improve the diagnosis and evaluation of cancer. Here, we propose a reusable biosensor based on a magnetic graphene oxide (MGO)-modified Au electrode to detect vascular endothelial growth factor (VEGF) in human plasma for cancer diagnosis. In this biosensor, Avastin is used as the specific biorecognition element, and MGO is used as the carrier for Avastin loading. The use of MGO enables rapid purification due to its magnetic properties, which prevents the loss of bioactivity. Moreover, the biosensor can be constructed quickly, without requiring a drying process, which is convenient for proceeding to detection. Our reusable biosensor provides the appropriate sensitivity for clinical diagnostics and has a wide range of linear detection, from 31.25-2000 pg mL(-1), compared to ELISA analysis. In addition, in experiments with 100% serum from clinical samples, readouts from the sensor and an ELISA for VEGF showed good correlation within the limits of the ELISA kit. The relative standard deviation (RSD) of the change in current (ΔC) for reproducibility of the Au biosensor was 2.36% (n=50), indicating that it can be reused with high reproducibility. Furthermore, the advantages of the Avastin-MGO-modified biosensor for VEGF detection are that it provides an efficient detection strategy that not only improves the detection ability but also reduces the cost and decreases the response time by 10-fold, indicating its potential as a diagnosis product.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Fator A de Crescimento do Endotélio Vascular / Grafite / Neoplasias Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Fator A de Crescimento do Endotélio Vascular / Grafite / Neoplasias Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article