Your browser doesn't support javascript.
loading
New suture materials for midline laparotomy closure: an experimental study.
Bellón, Juan M; Pérez-López, Paloma; Simón-Allue, Raquel; Sotomayor, Sandra; Pérez-Köhler, Bárbara; Peña, Estefanía; Pascual, Gemma; Calvo, Begoña.
Afiliação
  • Bellón JM; Departments of Surgery, Medical and Social Sciences, Faculty of Medicine and Health Sciences, University of Alcalá, Alcalá de Henares, Madrid, Spain. juanm.bellon@uah.es.
BMC Surg ; 14: 70, 2014 Sep 17.
Article em En | MEDLINE | ID: mdl-25231161
BACKGROUND: Midline laparotomy closure carries a significant risk of incisional hernia. This study examines the behavior of two new suture materials, an elastic material, polyurethane (PUe), and a barbed polydioxanone (PDXb) suture thread in a rabbit model of midline incision closure. METHODS: Three 2-cm midline incisions were made in 68 New Zealand White rabbits. The incisions were closed by running suture using four 3/0 threads: polypropylene (PP) (Surgipro®, Covidien), PUe (Assuplus®, Assut Europe), PDX (Assufil®, Assut Europe) or PDXb (Filbloc®, Assut Europe). Animals in each suture group were euthanized 3 weeks and 6 months after surgery. Histological sections of the tissue-embedded sutures were subjected to morphological, collagen expression, macrophage response and uniaxial tensiometry studies. RESULTS: No signs of wound dehiscence or complications were observed. At 3 weeks, all sutures were surrounded by connective tissue composed mainly of collagen III. PUe showed greater collagen I expression than the other sutures. All sutures elicited a macrophage response that diminished from 3 weeks to 6 months (p < 0.001). This response was similar for the non-reabsorbable sutures (PP and PUe) yet PDXb showed a significantly greater response than the other reabsorbable suture (PDX) at 3 weeks (p < 0.01). At this early time point, the tensile strength of PUe was similar to that of control intact tissue (p > 0.05). CONCLUSION: Three weeks after surgery, PUe revealed more collagen I deposition than the remaining materials and this translated to a similar biomechanical behavior to linea alba, that could avoid the appearance of short term dehiscences and thus reduce the incidence of incisional hernia. PDXb provides no additional advantages in their behavior regarding PDX suture.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Suturas / Técnicas de Sutura / Parede Abdominal / Hérnia Abdominal / Laparotomia Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Suturas / Técnicas de Sutura / Parede Abdominal / Hérnia Abdominal / Laparotomia Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article