Your browser doesn't support javascript.
loading
Detection and Identification of Six Foodborne Bacteria by Two-tube Multiplex Real Time PCR and Melting Curve Analysis.
Niu, Pei Hua; Zhang, Chen; Wang, Ji; Tan, Wen Jie; Ma, Xue Jun.
Afiliação
  • Niu PH; Key Laboratory for Medical Virology, Ministry of Health, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
  • Zhang C; Key Laboratory for Medical Virology, Ministry of Health, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
  • Wang J; Key Laboratory for Medical Virology, Ministry of Health, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
  • Tan WJ; Key Laboratory for Medical Virology, Ministry of Health, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
  • Ma XJ; Key Laboratory for Medical Virology, Ministry of Health, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
Biomed Environ Sci ; 27(10): 770-8, 2014 Oct.
Article em En | MEDLINE | ID: mdl-25341812
ABSTRACT

OBJECTIVE:

This study is aimed to develop a two-tube melting curve-based multiplex real time PCR assay (MCMRT-PCR) for the simultaneous detection of six common foodborne pathogenic bacteria (diarrhoeagenic Escherichia coli, Salmonella, and Shigella in tube 1, Staphylococcus aureus, Vibrio parahaemolyticus, and Listeria monocytogenes in tube 2).

METHODS:

A two-tube MCMRT-PCR assay was performed on 7900HT Fast Real-Time PCR System (Applied Biosystems, USA). Amplification by PCR was optimized to obtain high efficiency. The sensitivity and specificity of assays were investigated.

RESULTS:

The detection limit of optimized MCMRT-PCR assay was 3.9×102 CFU/mL for S. aureus, 4.4×102 CFU/mL for L. monocytogenes, 3.0×102 CFU/mL for Salmonella, 2.5×102 CFU/mL for Shigella, 2.1×102 CFU/mL for V. parahaemolyticus, and 1.2×102 CFU/mL for E. coli. The feasibility of MCMRT-PCR was further evaluated using artificially contaminated milk, the sensitivity was at the level of 105 CFU/mL.

CONCLUSION:

A two-tube MCMRT-PCR assay using six primer sets was developed for detection of multiple pathogens. Our findings demonstrates that the proposed two-tube assay is reliable, useful and rapid for simultaneous detection of six foodborne pathogenic bacteria with an intended application in provincial Centers for Diseases Control and Prevention (CDC).
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bactérias / Reação em Cadeia da Polimerase Multiplex / Reação em Cadeia da Polimerase em Tempo Real / Microbiologia de Alimentos Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bactérias / Reação em Cadeia da Polimerase Multiplex / Reação em Cadeia da Polimerase em Tempo Real / Microbiologia de Alimentos Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article