Your browser doesn't support javascript.
loading
Diagnostic accuracy of three sensory tests for diagnosis of sensory disturbances.
Li, Xiang-Ming; Yang, Yi; Hou, Yi; Yang, Jian-Tao; Qin, Ben-Gang; Fu, Guo; Gu, Li-Qiang.
Afiliação
  • Li XM; Department of Microsurgery and Orthopedic Trauma, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China.
  • Yang Y; Department of Microsurgery and Orthopedic Trauma, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China.
  • Hou Y; Department of Microsurgery and Orthopedic Trauma, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China.
  • Yang JT; Department of Microsurgery and Orthopedic Trauma, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China.
  • Qin BG; Department of Microsurgery and Orthopedic Trauma, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China.
  • Fu G; Department of Microsurgery and Orthopedic Trauma, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China.
  • Gu LQ; Department of Microsurgery and Orthopedic Trauma, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China.
J Reconstr Microsurg ; 31(1): 67-73, 2015 Jan.
Article em En | MEDLINE | ID: mdl-25423030
ABSTRACT

BACKGROUND:

Clinical diagnosis of sensory disturbances is extremely challenging, partly because the utility of sensory tests is questionable. Transection of C7 nerve root provides an objective assessment model to determine the diagnostic accuracy of sensory tests. The purpose of this study was to investigate the diagnostic accuracy of Semmes-Weinstein Monofilaments (SWM; Sammons Preston, Bolingbrook, IL), static two-point discrimination (s2PD), and current perception threshold (CPT) tests in patients with contralateral C7 nerve root transfer.

METHODS:

The contralateral index finger of patients was tested preoperatively and 6 weeks postoperatively, including the Revised Short-Form McGill Pain Questionnaire (SF-MPQ-2), SWM, s2PD, and CPT tests. The SF-MPQ-2 was used as a gold standard for sensory disturbances.

RESULTS:

A total of 38 patients were included in the study. The likelihood probability ratio of SWM and CPT tests generated small shifts in probability, whereas the s2PD test did not show any capacity to detect sensory disturbances. The areas under the curves (AUC) for SWM and CPT tests were 0.724 and 0.697, respectively. Based on different positive test standards, the AUCs for s2PD (≥ 6 mm) and s2PD (≥ 7 mm) tests were 0.632 and 0.658, respectively. When CPT and SWM tests were combined as a measure, the AUC increased to 0.763.

CONCLUSION:

The SWM and CPT tests show a small capacity to detect sensory disturbances, whereas the s2PD test does not show any diagnostic capacity. To better understand sensory disturbances, a comprehensive testing protocol including valid measures of physical impairment and symptom-specific measurement tools should be adopted.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pele / Transtornos de Sensação / Neuropatias do Plexo Braquial / Dedos / Monitorização Fisiológica Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pele / Transtornos de Sensação / Neuropatias do Plexo Braquial / Dedos / Monitorização Fisiológica Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article