Your browser doesn't support javascript.
loading
Chemical shift encoded imaging of hyperpolarized (13) C pyruvate.
Wiens, Curtis N; Friesen-Waldner, Lanette J; Wade, Trevor P; Sinclair, Kevin J; McKenzie, Charles A.
Afiliação
  • Wiens CN; Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
  • Friesen-Waldner LJ; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Ontario.
  • Wade TP; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Ontario.
  • Sinclair KJ; Robarts Research Institute, University of Western Ontario, London, Ontario.
  • McKenzie CA; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Ontario.
Magn Reson Med ; 74(6): 1682-9, 2015 Dec.
Article em En | MEDLINE | ID: mdl-25427313
PURPOSE: To demonstrate a reconstruction technique for separating signal from different hyperpolarized carbon-13 metabolites. METHODS: A reconstruction method is described for chemical shift encoded separation of the signal from pyruvate and its downstream metabolites. This method uses consistency of the data with the signal model rather than an additional free-induction decay (FID) acquisition to estimate the B0 offset. Compressed sensing was also integrated into the reconstruction allowing reconstruction of metabolite images from undersampled datasets. The performance of the reconstruction was assessed using thermal phantoms, digital phantoms, and in vivo hyperpolarized [1-(13) C] pyruvate experiments. RESULTS: Thermal and digital phantoms indicate that metabolite separation is feasible given Signal-to-noise ratio > 5 and an initial B0 offset estimate within -105 Hz to 90 Hz of the actual B0 offset. In vivo comparisons to an existing FID calibrated reconstruction show improved fidelity in regions with significant field map inhomogeneity provided that these field map variations are accounted for using an additional proton acquisition. Prospectively and retrospectively undersampled studies show acceleration factors of 2 are feasible using compressed sensing. CONCLUSION: A reconstruction framework for the separation of signal from pyruvate and its downstream metabolites is shown. This reconstruction eliminates the need to acquire additional calibration FID acquisition and allows acceleration through compressed sensing.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Ácido Pirúvico / Imagem Corporal Total / Imagem Molecular / Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Ácido Pirúvico / Imagem Corporal Total / Imagem Molecular / Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article