Your browser doesn't support javascript.
loading
Clinical profile and incidence of ventricular arrhythmia in patients undergoing defibrillator generator replacement in Spain.
Fontenla, Adolfo; López Gil, María; Martínez Ferrer, José; Alzueta, Javier; Fernández Lozano, Ignacio; Viñolas, Xavier; Rodríguez, Aníbal; Fernández de la Concha, Joaquín; Anguera, Ignasi; Arribas, Fernando.
Afiliação
  • Fontenla A; Unidad de Arritmias, Servicio de Cardiología, Hospital Universitario 12 de Octubre, Madrid, Spain. Electronic address: drfontenla@gmail.com.
  • López Gil M; Unidad de Arritmias, Servicio de Cardiología, Hospital Universitario 12 de Octubre, Madrid, Spain.
  • Martínez Ferrer J; Unidad de Arritmias, Servicio de Cardiología, Hospital Universitario Araba, Vitoria, Álava, Spain.
  • Alzueta J; Unidad de Arritmias, Servicio de Cardiología, Hospital Virgen de la Victoria, Málaga, Spain.
  • Fernández Lozano I; Unidad de Arritmias, Servicio de Cardiología, Hospital Universitario Puerta de Hierro, Majadahonda, Madrid, Spain.
  • Viñolas X; Unidad de Arritmias, Servicio de Cardiología, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.
  • Rodríguez A; Unidad de Arritmias, Servicio de Cardiología, Hospital Universitario de Canarias, Sta. Cruz de Tenerife, Spain.
  • Fernández de la Concha J; Unidad de Arritmias, Servicio de Cardiología, Hospital Infanta Cristina, Badajoz, Spain.
  • Anguera I; Unidad de Arritmias, Servicio de Cardiología, Hospital de Bellvitge, L'Hospitalet de Llobregat, Barcelona, Spain.
  • Arribas F; Unidad de Arritmias, Servicio de Cardiología, Hospital Universitario 12 de Octubre, Madrid, Spain.
Rev Esp Cardiol (Engl Ed) ; 67(12): 986-92, 2014 Dec.
Article em En | MEDLINE | ID: mdl-25432708
ABSTRACT
INTRODUCTION AND

OBJECTIVES:

Implantable cardioverter-defibrillators reduce mortality in some patients with heart disease. Battery replacement is a frequent occurrence in clinical practice and is required in up to 30% of implants. The benefit/risk ratio of defibrillators varies over time and should be reevaluated at the time of replacement. The aim of this study was to determine the clinical characteristics and incidence of defibrillator therapies in patients who underwent generator replacement.

METHODS:

This multicenter retrospective study involved patients from the UMBRELLA national registry who underwent replacement due to defibrillator battery depletion. The incidence of ventricular arrhythmias was determined via remote monitoring. Risk factors for sustained ventricular arrhythmia after replacement were analyzed.

RESULTS:

A total of 354 patients were included (mean age [standard deviation], 61.8 [14.5] years; men, 80%; secondary prevention, 42%; ventricular arrhythmias in the explanted generator, 62%). After a 25-month follow-up, 70 patients (20%) received appropriate therapies and 8 (2.3%) received inappropriate discharges. Male sex, structural heart disease, heart failure, and the absence of resynchronization were independent predictors of ventricular arrhythmia occurrence.

CONCLUSIONS:

One-fifth of patients had appropriate defibrillator therapies in the first 2 years after generator replacement. Determination of the factors associated with arrhythmia occurrence after replacement may be useful to optimize implantable cardioverter-defibrillator treatment.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Desfibriladores Implantáveis Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Desfibriladores Implantáveis Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2014 Tipo de documento: Article