Your browser doesn't support javascript.
loading
Rapid measurement of free cyanide in liquor by ion chromatography with pulsed amperometric detection.
Wu, Wenlin; Xiao, Quanwei; Zhang, Ping; Ye, Mei; Wan, Yuping; Liang, Hengxing.
Afiliação
  • Wu W; Department of Food, Chengdu Institute of Product Quality Inspection Co., Ltd., Chengdu, Sichuan 610100, China; Department of Food, Chengdu Product Quality Supervision and Inspection Institute, Chengdu, Sichuan 610100, China. Electronic address: 2008802@qq.com.
  • Xiao Q; Department of Food, Chengdu Institute of Product Quality Inspection Co., Ltd., Chengdu, Sichuan 610100, China; Department of Food, Chengdu Product Quality Supervision and Inspection Institute, Chengdu, Sichuan 610100, China.
  • Zhang P; Department of Food, Chengdu Institute of Product Quality Inspection Co., Ltd., Chengdu, Sichuan 610100, China; Department of Food, Chengdu Product Quality Supervision and Inspection Institute, Chengdu, Sichuan 610100, China.
  • Ye M; Department of Food, Chengdu Institute of Product Quality Inspection Co., Ltd., Chengdu, Sichuan 610100, China; Department of Food, Chengdu Product Quality Supervision and Inspection Institute, Chengdu, Sichuan 610100, China.
  • Wan Y; Department of Food, Chengdu Institute of Product Quality Inspection Co., Ltd., Chengdu, Sichuan 610100, China; Department of Food, Chengdu Product Quality Supervision and Inspection Institute, Chengdu, Sichuan 610100, China.
  • Liang H; Department of Food, Chengdu Institute of Product Quality Inspection Co., Ltd., Chengdu, Sichuan 610100, China; Department of Food, Chengdu Product Quality Supervision and Inspection Institute, Chengdu, Sichuan 610100, China.
Food Chem ; 172: 681-4, 2015 Apr 01.
Article em En | MEDLINE | ID: mdl-25442607
This study investigated the measurement of free cyanide in liquor by ion chromatography coupled with pulsed amperometric detection (IC-PAD). Eluent concentration, interferent evaluation and method performance were discussed. Results show that free cyanide in liquor can be rapidly determined by the optimised IC-PAD method. A sample requires only 1:100 dilution and simple filtration before being subjected to IC-PAD. The linear range is 1-5000 µg/L with an R value of 0.9998. The detection limit is 1 µg/L for a 25 µL injection loop. The overall relative standard deviation (RSD) of the method is less than 5%, and the recovery range is from 98.1% to 105.0%. This study has been proven significant and may have potential applications in liquors analysis.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cromatografia por Troca Iônica / Cianetos / Bebidas Alcoólicas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cromatografia por Troca Iônica / Cianetos / Bebidas Alcoólicas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2015 Tipo de documento: Article