Your browser doesn't support javascript.
loading
Laser-Doppler microvascular measurements in the peri-implant areas of different osseointegrated bone conductor implant systems.
Jarabin, János; Bere, Zsófia; Hartmann, Petra; Tóth, Ferenc; Kiss, József Géza; Rovó, László.
Afiliação
  • Jarabin J; Department of Otorhinolaryngology and Head-Neck Surgery, University of Szeged, Tisza Lajos körút 111., Szeged, 6725, Hungary. jarabinj@gmail.com.
  • Bere Z; Department of Otorhinolaryngology and Head-Neck Surgery, University of Szeged, Tisza Lajos körút 111., Szeged, 6725, Hungary.
  • Hartmann P; Institute of Surgical Research, University of Szeged, Szokefalvi-Nagy Béla utca 6., Szeged, 6720, Hungary.
  • Tóth F; Department of Otorhinolaryngology and Head-Neck Surgery, University of Szeged, Tisza Lajos körút 111., Szeged, 6725, Hungary.
  • Kiss JG; Department of Otorhinolaryngology and Head-Neck Surgery, University of Szeged, Tisza Lajos körút 111., Szeged, 6725, Hungary.
  • Rovó L; Department of Otorhinolaryngology and Head-Neck Surgery, University of Szeged, Tisza Lajos körút 111., Szeged, 6725, Hungary.
Eur Arch Otorhinolaryngol ; 272(12): 3655-62, 2015 Dec.
Article em En | MEDLINE | ID: mdl-25502915
ABSTRACT
The objective of this study was to evaluate the impact of hydroxyapatite coating of newly designed osseointegrated fixtures' abutments on the postoperative complication rates. The integrity of peri-implant microcirculation was used as a marker to compare tissue viability after different surgical techniques. Laser-Doppler Flowmetry (LDF) measures alone, and coupled with heat provocation tests were applied to test the different microcircular patterns. Measures for 17 consecutively implanted patients (8 women, 9 men, ages ranged from 18 to 77 years) were recruited; seven with soft tissue reduction (STR); and 10 with soft tissue preservation (STP).Thirteen non-operated retro-auricular areas were examined as naive controls. In isotherm conditions the baseline blood flow remained stable in all groups. The naive control patients demonstrated significant changes of blood flux in the intact skin. The non-implanted yet previously operated contralateral sides of the patients demonstrated marginally lower (p = 0.09) blood flux index. The STR sides however, showed significantly lower (average 217 %) provoked blood flux compared to controls (p < 0.001). At the STP sides a maladaptation could be observed (average 316 %) compared to the contralateral sides (p = 0.53). STP sides demonstrated a significantly better blood flow improvement compared to the STR sides (p = 0.02). These results suggest a favorable postoperative condition of vascular microcirculation after STP, than after STR surgery. The possibly faster wound healing and lower potential complication rate may widen the inclusion criteria and maybe beneficial for the patient compliance with a better quality-of-life.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Fluxometria por Laser-Doppler / Implantação de Prótese / Auxiliares de Audição / Perda Auditiva Condutiva / Microcirculação Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Fluxometria por Laser-Doppler / Implantação de Prótese / Auxiliares de Audição / Perda Auditiva Condutiva / Microcirculação Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article