Your browser doesn't support javascript.
loading
Influence of clinical experience of the Macintosh laryngoscope on performance with the Pentax-AWS Airway Scope(®), a rigid video-laryngoscope, by paramedics in Japan.
Ota, Kohei; Sadamori, Takuma; Kusunoki, Shinji; Otani, Tadatsugu; Tamura, Tomoko; Une, Kazunobu; Kida, Yoshiko; Itai, Junji; Iwasaki, Yasumasa; Hirohashi, Nobuyuki; Nakao, Masakazu; Tanigawa, Koichi.
Afiliação
  • Ota K; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima, 734-8551, Japan. kota@hiroshima-u.ac.jp.
  • Sadamori T; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima, 734-8551, Japan.
  • Kusunoki S; Emergency Medical Center, Hiroshima Prefectural Hospital, Hiroshima, Japan.
  • Otani T; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima, 734-8551, Japan.
  • Tamura T; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima, 734-8551, Japan.
  • Une K; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima, 734-8551, Japan.
  • Kida Y; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima, 734-8551, Japan.
  • Itai J; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima, 734-8551, Japan.
  • Iwasaki Y; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima, 734-8551, Japan.
  • Hirohashi N; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima, 734-8551, Japan.
  • Nakao M; Department of Anesthesiology, Hiroshima General Hospital, Hiroshima, Japan.
  • Tanigawa K; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima, 734-8551, Japan.
J Anesth ; 29(5): 672-7, 2015 Oct.
Article em En | MEDLINE | ID: mdl-25527323
ABSTRACT

PURPOSE:

We sought to establish the clinical utility of the Pentax-AWS Airway Scope(®) (AWS) when used by paramedics to intubate the trachea, and to evaluate whether their performance was influenced by previous clinical experience with the Macintosh laryngoscope (ML).

METHODS:

Twenty paramedics attempted tracheal intubation using the AWS in five patients each in the operating room. We recorded the success rate, the number of intubation attempts, and the time for intubation and adverse events, and compared these based on the paramedics' previous clinical experience with the ML. Ten paramedics had no prior clinical experience of the ML (group A) and 10 had used it on more than 30 occasions (group B).

RESULTS:

The intubation success rate was 99 % (99/100). Notably, 96 % (47/49) of intubations were achieved on the first attempt by the inexperienced paramedics in group A, compared with 64 % (32/50) by the experienced paramedics in group B (p = 0.0001). The time to intubation (mean ± SD) was significantly shorter in group A than in group B (37 ± 24 vs. 48 ± 21 s, p = 0.002). There were marked variations in the times taken to intubate, but no apparent improvement as the intubators gained experience between their first and fifth cases. No complications were encountered in either group.

CONCLUSION:

We found that paramedics could achieve a high tracheal intubation success rate using the AWS independent of previous airway management experience. Better intubation performance with the AWS was observed in paramedics without clinical experience with the ML.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Laringoscópios / Pessoal Técnico de Saúde / Intubação Intratraqueal / Laringoscopia Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País como assunto: Asia Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Laringoscópios / Pessoal Técnico de Saúde / Intubação Intratraqueal / Laringoscopia Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País como assunto: Asia Idioma: En Ano de publicação: 2015 Tipo de documento: Article