Adjusting tidal volume to stress index in an open lung condition optimizes ventilation and prevents overdistension in an experimental model of lung injury and reduced chest wall compliance.
Ferrando, Carlos; Suárez-Sipmann, Fernando; Gutierrez, Andrea; Tusman, Gerardo; Carbonell, Jose; García, Marisa; Piqueras, Laura; Compañ, Desamparados; Flores, Susanie; Soro, Marina; Llombart, Alicia; Belda, Francisco Javier.
Afiliação
  • Ferrando C; Anesthesiology and Critical Care Department, Hospital Clínico Universitario of Valencia, Av. Blasco Ibañez, 17, Valencia, CP: 46010, Spain. cafeoranestesia@gmail.com.
  • Suárez-Sipmann F; Section of Anesthesiology and Critical Care, Uppsala University Hospital Uppsala, Uppsala, Sweden. fsuarezsipmann@gmail.com.
  • Gutierrez A; CIBER de Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain. fsuarezsipmann@gmail.com.
  • Tusman G; Anesthesiology and Critical Care Department, Hospital Clínico Universitario of Valencia, Av. Blasco Ibañez, 17, Valencia, CP: 46010, Spain. andreguti@hotmail.com.
  • Carbonell J; Department of Anesthesiology, Hospital Privado de Comunidad, Mar de Plata, Argentina. gtusman@hotmail.com.
  • García M; Anesthesiology and Critical Care Department, Hospital Clínico Universitario of Valencia, Av. Blasco Ibañez, 17, Valencia, CP: 46010, Spain. joseacarbonell19@hotmail.com.
  • Piqueras L; Anesthesiology and Critical Care Department, Hospital Clínico Universitario of Valencia, Av. Blasco Ibañez, 17, Valencia, CP: 46010, Spain. marisagarciap@gmail.com.
  • Compañ D; Clinical Research Foundation, Hospital Clínico Universitario of Valencia, Valencia, Spain. lpiqueras70@hotmail.com.
  • Flores S; Pathological Anatomy Department, Hospital Clínico Universitario of Valencia, Valencia, Spain. company_amp@gva.es.
  • Soro M; Radiology Department, Hospital Clinico Universitario of Valencia, Valencia, Spain. susaniefc@gmail.com.
  • Llombart A; Anesthesiology and Critical Care Department, Hospital Clínico Universitario of Valencia, Av. Blasco Ibañez, 17, Valencia, CP: 46010, Spain. soromarina@gmail.com.
  • Belda FJ; Clinical Research Foundation, Hospital Clínico Universitario of Valencia, Valencia, Spain. allombart@incliva.es.
Crit Care ; 19: 9, 2015 Jan 13.
Article em En | MEDLINE | ID: mdl-25583125
ABSTRACT

INTRODUCTION:

The stress index (SI), a parameter derived from the shape of the pressure-time curve, can identify injurious mechanical ventilation. We tested the hypothesis that adjusting tidal volume (VT) to a non-injurious SI in an open lung condition avoids hypoventilation while preventing overdistension in an experimental model of combined lung injury and low chest-wall compliance (Ccw).

METHODS:

Lung injury was induced by repeated lung lavages using warm saline solution, and Ccw was reduced by controlled intra-abdominal air-insufflation in 22 anesthetized, paralyzed and mechanically ventilated pigs. After injury animals were recruited and submitted to a positive end-expiratory pressure (PEEP) titration trial to find the PEEP level resulting in maximum compliance. During a subsequent four hours of mechanical ventilation, VT was adjusted to keep a plateau pressure (Pplat) of 30 cmH2O (Pplat-group, n = 11) or to a SI between 0.95 and 1.05 (SI-group, n = 11). Respiratory rate was adjusted to maintain a 'normal' PaCO2 (35 to 65 mmHg). SI, lung mechanics, arterial-blood gases haemodynamics pro-inflammatory cytokines and histopathology were analyzed. In addition Computed Tomography (CT) data were acquired at end expiration and end inspiration in six animals.

RESULTS:

PaCO2 was significantly higher in the Pplat-group (82 versus 53 mmHg, P = 0.01), with a resulting lower pH (7.19 versus 7.34, P = 0.01). We observed significant differences in VT (7.3 versus 5.4 mlKg(-1), P = 0.002) and Pplat values (30 versus 35 cmH2O, P = 0.001) between the Pplat-group and SI-group respectively. SI (1.03 versus 0.99, P = 0.42) and end-inspiratory transpulmonary pressure (PTP) (17 versus 18 cmH2O, P = 0.42) were similar in the Pplat- and SI-groups respectively, without differences in overinflated lung areas at end- inspiration in both groups. Cytokines and histopathology showed no differences.

CONCLUSIONS:

Setting tidal volume to a non-injurious stress index in an open lung condition improves alveolar ventilation and prevents overdistension without increasing lung injury. This is in comparison with limited Pplat protective ventilation in a model of lung injury with low chest-wall compliance.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Volume de Ventilação Pulmonar / Respiração com Pressão Positiva / Parede Torácica / Lesão Pulmonar Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Volume de Ventilação Pulmonar / Respiração com Pressão Positiva / Parede Torácica / Lesão Pulmonar Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article