Your browser doesn't support javascript.
loading
Fluoroscopy integrated 3D mapping significantly reduces radiation exposure during ablation for a wide spectrum of cardiac arrhythmias.
Christoph, Marian; Wunderlich, Carsten; Moebius, Stefanie; Forkmann, Mathias; Sitzy, Judith; Salmas, Jozef; Mayer, Julia; Huo, Yan; Piorkowski, Christopher; Gaspar, Thomas.
Afiliação
  • Christoph M; Department of Electrophysiology, Heart Center Dresden, University of Dresden, University of Technology Dresden, Fetscherstrasse 76, Dresden 01307, Germany marian.christoph@mailbox.tu-dresden.de.
  • Wunderlich C; Department of Electrophysiology, Heart Center Dresden, University of Dresden, University of Technology Dresden, Fetscherstrasse 76, Dresden 01307, Germany.
  • Moebius S; Department of Electrophysiology, Heart Center Dresden, University of Dresden, University of Technology Dresden, Fetscherstrasse 76, Dresden 01307, Germany.
  • Forkmann M; Department of Electrophysiology, Heart Center Dresden, University of Dresden, University of Technology Dresden, Fetscherstrasse 76, Dresden 01307, Germany.
  • Sitzy J; Department of Electrophysiology, Heart Center Dresden, University of Dresden, University of Technology Dresden, Fetscherstrasse 76, Dresden 01307, Germany.
  • Salmas J; Department of Electrophysiology, Heart Center Dresden, University of Dresden, University of Technology Dresden, Fetscherstrasse 76, Dresden 01307, Germany.
  • Mayer J; Department of Electrophysiology, Heart Center Dresden, University of Dresden, University of Technology Dresden, Fetscherstrasse 76, Dresden 01307, Germany.
  • Huo Y; Department of Electrophysiology, Heart Center Dresden, University of Dresden, University of Technology Dresden, Fetscherstrasse 76, Dresden 01307, Germany.
  • Piorkowski C; Steinbeis Research Institute-Electrophysiology and Cardiac Devices, Fetscherstrasse 111, 01307 Dresden, Germany.
  • Gaspar T; Steinbeis Research Institute-Electrophysiology and Cardiac Devices, Fetscherstrasse 111, 01307 Dresden, Germany.
Europace ; 17(6): 928-37, 2015 Jun.
Article em En | MEDLINE | ID: mdl-25609207
AIMS: Despite the use of established 3D-mapping systems, invasive electrophysiological studies and catheter ablation require high radiation exposure of patients and medical staff. This study investigated whether electroanatomic catheter tracking in prerecorded X-ray images on top of an existing 3D-mapping system has any impact on radiation exposure. METHODS AND RESULTS: Two hundred and ninety-five consecutive patients were either ablated with the guidance of the traditional CARTO-3 system (c3) or with help of the CARTO-UNIVU system (cU): [typical atrial flutter (AFL) n = 58, drug refractory atrial fibrillation (AF) n = 81, ectopic atrial tachycardia (EAT) n = 37, accessory pathways (APs) n = 22, symptomatic, idiopathic premature ventricular complexes (PVCs) n = 56, ventricular tachycardias (VTs) n = 41]. The CARTO-UNIVU allowed a reduction in radiation exposure: fluoroscopy time: AFL c3: 8.6 ± 0.8 min vs. cU: 2.9 ± 0.3 min, P < 0.001; AF c3: 16.0 ± 1.3 min vs. cU: 6.4 ± 0.9 min, P < 0.001; EAT c3: 23.4 ± 3.1 min vs. cU: 9.7 ± 1.7 min, P < 0.001; AP c3: 7.1 ± 1.2 min vs. cU: 6.0 ± 1.5 min, P = 0.59; PVCs c3: 17.6 ± 2.3 min vs. cU: 15.2 ± 2.8 min, P = 0.52; VT c3: 31.4 ± 3.4 min vs. cU: 17.5 ± 2.4 min, P = 0.003. Corresponding to the fluoroscopy time the fluoroscopy dose was also reduced significantly. These advantages were not at the cost of increased procedure times, periprocedural complications, or decreased acute ablation success rates. CONCLUSION: In a wide spectrum of cardiac arrhythmias, and especially in AF and VT ablation, fluoroscopy integrated 3D mapping contributed to a dramatic reduction in radiation exposure without prolonging procedure times and compromising patient's safety. That effect, however, could not be maintained in patients with APs and PVCs.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Doses de Radiação / Fluoroscopia / Ablação por Cateter / Exposição à Radiação / Imageamento Tridimensional Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Doses de Radiação / Fluoroscopia / Ablação por Cateter / Exposição à Radiação / Imageamento Tridimensional Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article