Your browser doesn't support javascript.
loading
Improved accuracy of 3D-printed navigational template during complicated tibial plateau fracture surgery.
Huang, Huajun; Hsieh, Ming-Fa; Zhang, Guodong; Ouyang, Hanbin; Zeng, Canjun; Yan, Bin; Xu, Jing; Yang, Yang; Wu, Zhanglin; Huang, Wenhua.
Afiliação
  • Huang H; Department of Anatomy, Guangdong Provincial Key Laboratory of Medical Biomechanics, School of Basic Medical Sciences, Southern Medical University, North-1838, Guangzhou, 510515, China, tianjixuanying@163.com.
Australas Phys Eng Sci Med ; 38(1): 109-17, 2015 Mar.
Article em En | MEDLINE | ID: mdl-25663390
ABSTRACT
This study was aimed to improve the surgical accuracy of plating and screwing for complicated tibial plateau fracture assisted by 3D implants library and 3D-printed navigational template. Clinical cases were performed whereby complicated tibial plateau fractures were imaged using computed tomography and reconstructed into 3D fracture prototypes. The preoperative planning of anatomic matching plate with appropriate screw trajectories was performed with the help of the library of 3D models of implants. According to the optimal planning, patient-specific navigational templates produced by 3D printer were used to accurately guide the real surgical implantation. The fixation outcomes in term of the deviations of screw placement between preoperative and postoperative screw trajectories were measured and compared, including the screw lengths, entry point locations and screw directions. With virtual preoperative planning, we have achieved optimal and accurate fixation outcomes in the real clinical surgeries. The deviations of screw length was 1.57 ± 5.77 mm, P > 0.05. The displacements of the entry points in the x-, y-, and z-axis were 0.23 ± 0.62, 0.83 ± 1.91, and 0.46 ± 0.67 mm, respectively, P > 0.05. The deviations of projection angle in the coronal (x-y) and transverse (x-z) planes were 6.34 ± 3.42° and 4.68 ± 3.94°, respectively, P > 0.05. There was no significant difference in the deviations of screw length, entry point and projection angle between the ideal and real screw trajectories. The ideal and accurate preoperative planning of plating and screwing can be achieved in the real surgery assisted by the 3D models library of implants and the patient-specific navigational template. This technology improves the accuracy and efficiency of personalized internal fixation surgery and we have proved this in our clinical applications.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fraturas da Tíbia / Fixadores Internos / Cirurgia Assistida por Computador / Impressão Tridimensional / Fixação Interna de Fraturas Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fraturas da Tíbia / Fixadores Internos / Cirurgia Assistida por Computador / Impressão Tridimensional / Fixação Interna de Fraturas Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article