Evaluation of the dose perturbation around gold and steel fiducial markers in a medical linac through Geant4 Monte Carlo simulation.
Pontoriero, Antonio; Amato, Ernesto; Iatí, Giuseppe; De Renzis, Costantino; Pergolizzi, Stefano.
Afiliação
  • Pontoriero A; Department of Biomedical Sciences and of Morphologic and Functional Imaging, University of Messina, Messina, Italy Radiotherapy Unit, University Hospital "G. Martino", Messina, Italy.
  • Amato E; Department of Biomedical Sciences and of Morphologic and Functional Imaging, University of Messina, Messina, Italy.
  • Iatí G; Radiotherapy Unit, University Hospital "G. Martino", Messina, Italy.
  • De Renzis C; Department of Biomedical Sciences and of Morphologic and Functional Imaging, University of Messina, Messina, Italy Radiotherapy Unit, University Hospital "G. Martino", Messina, Italy.
  • Pergolizzi S; Department of Biomedical Sciences and of Morphologic and Functional Imaging, University of Messina, Messina, Italy Radiotherapy Unit, University Hospital "G. Martino", Messina, Italy.
J Xray Sci Technol ; 23(2): 135-40, 2015.
Article em En | MEDLINE | ID: mdl-25882726
OBJECTIVE: Purpose of this work was to study the dose perturbation within the target volume of a external MV radiation therapy when using metal fiducials. METHODS: We developed a Monte Carlo simulation in Geant4 of a cylindrical fiducial made either of gold or of steel and simulated the photon irradiation beam originating from a medical Linac operating at 6, 10 or 15 MV. For each energy, two different irradiation schemes were simulated: a single 5 × 5-cm square field in the -x direction, and five 5 × 5-cm fields at 0°, 80°, 165°, 195° and 280°. RESULTS: In a single beam irradiation scheme, we observed a dose reduction behind fiducials varying from -20% for gold at 6 MV to -5% for steel at 15 MV, and a dose increment in front of the fiducial ranging from +33% for gold at 15 MV to +10% for steel at 6 MV. When five beams were employed, a dose increment ranging from +28% to +46% has been found around gold. Around a steel fiducial, an average increment of +17% was found, irrespective of the photon energy. CONCLUSIONS: When using a single beam, the decrement of dose behind both steel and gold markers increases with the photon energy. This effect vanishes when a multifield treatment is delivered; in this instance there is a dose increment around fiducials, according to both fiducial material and photon energy, with lower values for steel and 6 MV. This energy represents the best choice when fiducial markers are present inside the irradiated volume.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aço / Simulação por Computador / Planejamento da Radioterapia Assistida por Computador / Método de Monte Carlo / Marcadores Fiduciais / Ouro Tipo de estudo: Health_economic_evaluation Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aço / Simulação por Computador / Planejamento da Radioterapia Assistida por Computador / Método de Monte Carlo / Marcadores Fiduciais / Ouro Tipo de estudo: Health_economic_evaluation Idioma: En Ano de publicação: 2015 Tipo de documento: Article