Sensitivity of susceptibility-weighted imaging in detecting superparamagnetic iron oxide-labeled mesenchymal stem cells: a comparative study.
Park, Serah; Kwak, Byung Kook; Jung, Jisung.
Afiliação
  • Park S; Department of Radiology, Chung-Ang University College of Medicine, Seoul, Korea.
  • Kwak BK; Department of Radiology, Chung-Ang University College of Medicine, Seoul, Korea ; Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea.
  • Jung J; Department of Radiology, Chung-Ang University College of Medicine, Seoul, Korea.
Iran J Radiol ; 12(2): e20782, 2015 Apr.
Article em En | MEDLINE | ID: mdl-25901258
ABSTRACT

BACKGROUND:

Susceptibility-weighted imaging (SWI) is extremely sensitive in the detection of superparamagnetic iron oxide (SPIO) nanoparticle-labeled cells. However, no study has compared molecular imaging for stem cell detection using SWI and other MRI pulse sequences.

OBJECTIVES:

This study aims to assess the sensitivity of SWI in detecting SPIO nanoparticle-labeled, human bone marrow-derived mesenchymal stem cells (SPIO-hMSCs) compared with that of T2- and T2*-weighted imaging (T2WI and T2*WI, respectively) in a phantom and in vivo study in rats. MATERIALS AND

METHODS:

A phantom was prepared with various cell concentrations. In one normal rat, SPIO-hMSCs were implanted directly through burr holes into both caudate putamens, while in three rats without and six rats with photothrombotic infarction, 2.5 × 10(5)/ml SPIO-hMSCs were infused into the ipsilateral internal carotid artery (ICA). T2WI, T2*WI, and SWI findings were compared for dark regions representing SPIO-hMSCs.

RESULTS:

SWI and T2*WI detected 15 µL of 13 SPIO-hMSCs/µL and 15 µL of 27 SPIO-hMSCs/µL in the phantom, respectively and 3 µL of 333 SPIO-hMSCs/µL and 3 µL of 167 SPIO-hMSCs/µL in the normal rat brain (direct implantation). In the normal rat brain (ICA infusion), one of the three cases showed numerous foci of dark regions dispersed throughout the brain on T2*WI and SWI. Dark regions surrounded the infarcts in all six infracted rat brains. The dark region was most prominent on SWI, followed by T2*WI and T2WI in all six rats (P = 0.002). Implanted SPIO-hMSCs were confirmed using Prussian blue staining.

CONCLUSIONS:

SWI is the most sensitive in the detection of SPIO-hMSCs, with the dark regions representing SPIO-hMSCs being more prominent on SWI than on T2*WI and T2WI.