Your browser doesn't support javascript.
loading
Multiplexed peptide analysis using data-independent acquisition and Skyline.
Egertson, Jarrett D; MacLean, Brendan; Johnson, Richard; Xuan, Yue; MacCoss, Michael J.
Afiliação
  • Egertson JD; Department of Genome Sciences, University of Washington, Seattle, Washington, USA.
  • MacLean B; Department of Genome Sciences, University of Washington, Seattle, Washington, USA.
  • Johnson R; Department of Genome Sciences, University of Washington, Seattle, Washington, USA.
  • Xuan Y; Thermo Fisher Scientific (Bremen) GmbH, Bremen, Germany.
  • MacCoss MJ; Department of Genome Sciences, University of Washington, Seattle, Washington, USA.
Nat Protoc ; 10(6): 887-903, 2015 Jun.
Article em En | MEDLINE | ID: mdl-25996789
Here we describe the use of data-independent acquisition (DIA) on a Q-Exactive mass spectrometer for the detection and quantification of peptides in complex mixtures using the Skyline Targeted Proteomics Environment (freely available online at http://skyline.maccosslab.org). The systematic acquisition of mass spectrometry (MS) or tandem MS (MS/MS) spectra by DIA is in contrast to DDA, in which the acquired MS/MS spectra are only suitable for the identification of a stochastically sampled set of peptides. Similarly to selected reaction monitoring (SRM), peptides can be quantified from DIA data using targeted chromatogram extraction. Unlike SRM, data acquisition is not constrained to a predetermined set of target peptides. In this protocol, a spectral library is generated using data-dependent acquisition (DDA), and chromatograms are extracted from the DIA data for all peptides in the library. As in SRM, quantification using DIA data is based on the area under the curve of extracted MS/MS chromatograms. In addition, a quality control (QC) method suitable for DIA based on targeted MS/MS acquisition is detailed. Not including time spent acquiring data, and time for database searching, the procedure takes ∼1-2 h to complete. Typically, data acquisition requires roughly 1-4 h per sample, and a database search will take 0.5-2 h to complete.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Peptídeos / Espectrometria de Massas / Software / Biblioteca de Peptídeos Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Peptídeos / Espectrometria de Massas / Software / Biblioteca de Peptídeos Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2015 Tipo de documento: Article