Your browser doesn't support javascript.
loading
Direct determination of the nutrient profile in plant materials by femtosecond laser-induced breakdown spectroscopy.
de Carvalho, Gabriel Gustinelli Arantes; Moros, Javier; Santos, Dário; Krug, Francisco José; Laserna, J Javier.
Afiliação
  • de Carvalho GG; University of São Paulo, NAPTISA Research Support Center "Technology and Innovation for a Sustainable Agriculture", Center for Nuclear Energy in Agriculture, Av. Centenário 303, 13416-000 Piracicaba, SP, Brazil.
  • Moros J; Universidad de Málaga, Departamento de Química Analítica, E-29071 Málaga, Spain.
  • Santos D; Federal University of São Paulo, Diadema, SP, Brazil.
  • Krug FJ; University of São Paulo, NAPTISA Research Support Center "Technology and Innovation for a Sustainable Agriculture", Center for Nuclear Energy in Agriculture, Av. Centenário 303, 13416-000 Piracicaba, SP, Brazil.
  • Laserna JJ; Universidad de Málaga, Departamento de Química Analítica, E-29071 Málaga, Spain. Electronic address: laserna@uma.es.
Anal Chim Acta ; 876: 26-38, 2015 May 30.
Article em En | MEDLINE | ID: mdl-25998455
Femtosecond laser-induced breakdown spectroscopy (fs-LIBS) has been used for the first time for quantitative determination of nutrients in plant materials from different crops. A highly heterogeneous population of 31 samples, previously analyzed by inductively coupled plasma optical emission spectroscopy, covering a wide range of matrices was interrogated. To tackle the analysis, laser-induced plasmas under argon atmosphere of pellets prepared from sieved cryogenically ground leaves were studied. Predictive functions based on univariate and multivariate modeling of optical emissions associated to macro- (Ca, Mg, and P) and micronutrients (Cu, Fe, Mn and Zn) were designed. Hierarchical cluster analysis was performed to select representative calibration (n(cal)=17) and validation (n(val)=14) datasets. The predictive performance of calibration functions over fs-LIBS data was compared with that attained on spectral information from nanosecond LIBS (ns-LIBS) operating at different wavelengths (1064 nm, 532 nm, and 266 nm). Findings established higher accuracy and less uncertainty on mass fractions quantification from fs-LIBS, whatever the modeling approach. Quality coefficients below 20% for the accuracy error on mass fractions' prediction in unknown samples, and residual predictive deviations in general above 5, were obtained. In contrast, only multivariate modeling satisfactorily handled the non-linear variations of emissions in ns-LIBS, leading to 2-fold decrease in the root mean square error of prediction (RMSEP) of Ca, Mg, P, Cu, Fe, Mn and Zn in comparison with the univariate approach. But still, an averaged quality coefficient about 35% and residual predictive deviations below 3 were found. Similar predictive capabilities were observed when changing the laser wavelength. Although predicted values by ns-LIBS multivariate modeling exhibit better agreement with reference mass fractions as compared to univariate functions, fs-LIBS conducts better quantification of nutrients in plant materials since it is less dependent on the chemical composition of the matrices.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fósforo / Oligoelementos / Cálcio / Produtos Agrícolas / Magnésio Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fósforo / Oligoelementos / Cálcio / Produtos Agrícolas / Magnésio Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2015 Tipo de documento: Article