Your browser doesn't support javascript.
loading
Supreme Laryngeal Mask Airway versus Face Mask during Neonatal Resuscitation: A Randomized Controlled Trial.
Trevisanuto, Daniele; Cavallin, Francesco; Nguyen, Loi Ngoc; Nguyen, Tien Viet; Tran, Linh Dieu; Tran, Chien Dinh; Doglioni, Nicoletta; Micaglio, Massimo; Moccia, Luciano.
Afiliação
  • Trevisanuto D; Department of Women and Children Health, University of Padua, Azienda Ospedaliera di Padova, Padova, Italy; Amici della Neonatologia Trentina, Trento, Italy. Electronic address: trevo@pediatria.unipd.it.
  • Cavallin F; Independent Statistician, Padova, Italy.
  • Nguyen LN; Department of Neonatal Intensive Care, National Hospital of Obstetrics and Gynecology, Ha Noi, Viet Nam.
  • Nguyen TV; Department of Neonatal Intensive Care, National Hospital of Obstetrics and Gynecology, Ha Noi, Viet Nam.
  • Tran LD; Department of Neonatal Intensive Care, National Hospital of Obstetrics and Gynecology, Ha Noi, Viet Nam.
  • Tran CD; Breath of Life Program - East Meets West Foundation, Oakland, CA.
  • Doglioni N; Department of Women and Children Health, University of Padua, Azienda Ospedaliera di Padova, Padova, Italy.
  • Micaglio M; Department of Anesthesia and Intensive Care, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy.
  • Moccia L; Amici della Neonatologia Trentina, Trento, Italy; Breath of Life Program - East Meets West Foundation, Oakland, CA.
J Pediatr ; 167(2): 286-91.e1, 2015 Aug.
Article em En | MEDLINE | ID: mdl-26003882
ABSTRACT

OBJECTIVE:

To assess the effectiveness of supreme laryngeal mask airway (SLMA) over face mask ventilation for preventing need for endotracheal intubation at birth. STUDY

DESIGN:

We report a prospective, randomized, parallel 11, unblinded, controlled trial. After a short-term educational intervention on SLMA use, infants ≥34-week gestation and/or expected birth weight ≥1500 g requiring positive pressure ventilation (PPV) at birth were randomized to resuscitation by SLMA or face mask. The primary outcome was the success rate of the resuscitation devices (SLMA or face mask) defined as the achievement of an effective PPV preventing the need for endotracheal intubation.

RESULTS:

We enrolled 142 patients (71 in SLMA and 71 in face mask group, respectively). Successful resuscitation rate was significantly higher with the SLMA compared with face mask ventilation (91.5% vs 78.9%; P = .03). Apgar score at 5 minutes was significantly higher in SLMA than in face mask group (P = .02). Neonatal intensive care unit admission rate was significantly lower in SLMA than in face mask group (P = .02). No complications related to the procedure occurred.

CONCLUSIONS:

In newborns with gestational age ≥34 weeks and/or expected birth weight ≥1500 g needing PPV at birth, the SLMA is more effective than face mask to prevent endotracheal intubation. The SLMA is effective in clinical practice after a short-term educational intervention. TRIAL REGISTRATION Registered with ClinicalTrials.gov NCT01963936.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ressuscitação / Respiração com Pressão Positiva / Máscaras Laríngeas / Intubação Intratraqueal / Máscaras Tipo de estudo: Clinical_trials / Observational_studies Limite: Female / Humans / Male / Newborn País como assunto: Asia Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ressuscitação / Respiração com Pressão Positiva / Máscaras Laríngeas / Intubação Intratraqueal / Máscaras Tipo de estudo: Clinical_trials / Observational_studies Limite: Female / Humans / Male / Newborn País como assunto: Asia Idioma: En Ano de publicação: 2015 Tipo de documento: Article