Your browser doesn't support javascript.
loading
Novel high-sensitivity troponin assay requires higher cut-off value to separate acute myocardial infarction from non-acute myocardial infarction in a high-risk population.
Wassef, Anthony Wafik Aziz; Hiebert, Brett; Saeed, Mahwash F; Tam, James W.
Afiliação
  • Wassef AW; Section of Cardiology, Department of Internal Medicine, College of Medicine, Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada.
  • Hiebert B; Section of Cardiology, Department of Internal Medicine, College of Medicine, Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada.
  • Saeed MF; Section of Cardiology, Department of Internal Medicine, College of Medicine, Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada.
  • Tam JW; Section of Cardiology, Department of Internal Medicine, College of Medicine, Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada.
Can J Physiol Pharmacol ; 93(10): 873-7, 2015 Oct.
Article em En | MEDLINE | ID: mdl-26097995
PURPOSE: The novel high-sensitivity troponin T assay (hs-cTnT) has been validated for diagnosing AMI in the emergency room. However its utility in high-risk in-patient populations is unknown. METHODS: We retrospectively reviewed admissions to a general cardiology unit that had 2 hs-cTnT measurements in the first 12 h of presentation. We assessed 8 diagnostic algorithms that used hs-cTnT concentration and changes in concentration (including the 99th percentile cut-off of 14 ng/L) for their diagnostic utility in separating AMI patients from cardiac/nonACS and non-cardiac chest-pain patients. UA was excluded. RESULTS: There were 233 patients (mean age 67 years, 153 were males (66%)) admitted over a 2 month period, with AMI diagnosed in 118 of these patients (51%). The recommended 99th percentile cut-off had modest accuracy (65%), good sensitivity (88%), and poor specificity (25%); a higher cut-off of 75 ng/L had a better diagnostic accuracy of 73%, p < 0.05. While some hs-cTnT algorithms were either highly sensitive or specific, none were both. CONCLUSION: In high-risk cardiology in-patients, no hs-cTnT concentration cut-off or change more accurately diagnosed and excluded AMI, although higher cut-offs had better diagnostic utility.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Índice de Gravidade de Doença / Troponina T / Infarto do Miocárdio Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Índice de Gravidade de Doença / Troponina T / Infarto do Miocárdio Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2015 Tipo de documento: Article