Your browser doesn't support javascript.
loading
Surgical removal of guidewire entrapped within stent struts during percutaneous coronary angioplasty.
Oruc, Onk Alper; Aksüt, Mehmet; Bakirci, Eftal Murat; Ekren, Halil; Erkut, Bilgehan.
Afiliação
  • Oruc OA; Department of Cardiovascular Surgery, Erzincan University Medical Faculty, Mengucek Gazi Education and Research Hospital, Erzincan. oralponk99@yahoo.com.
Heart Surg Forum ; 18(3): E106-8, 2015 Jun 26.
Article em En | MEDLINE | ID: mdl-26115154
ABSTRACT
There has been a growing trend toward percutaneous coronary angioplasty for complex coronary artery lesions. Stent or guidewire break off or trapping within the coronary artery lumen is a rare complication, but it may have fatal consequences. In such cases, the entrapped device may be removed by either percutaneous route or surgical exploration. Here, we report a patient with guidewire entrapment within the struts of the intracoronary stent during primary percutaneous coronary angioplasty, which necessitated surgical removal and subsequent coronary artery bypass grafting (CABG).
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Stents / Remoção de Dispositivo / Síndrome Coronariana Aguda Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Stents / Remoção de Dispositivo / Síndrome Coronariana Aguda Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article