Your browser doesn't support javascript.
loading
Nanoparticles for Radiation Therapy Enhancement: the Key Parameters.
Retif, Paul; Pinel, Sophie; Toussaint, Magali; Frochot, Céline; Chouikrat, Rima; Bastogne, Thierry; Barberi-Heyob, Muriel.
Afiliação
  • Retif P; 1. CHR Metz-Thionville, Hôpital de Mercy, Service de radiothérapie, 1 allée du Château, Ars-Laquenexy, 57530, France; ; 2. Université de Lorraine, CRAN, UMR 7039, Campus Sciences, BP 70239, Vandœuvre-lès-Nancy Cedex, 54506, France; ; 3. CNRS, CRAN, UMR 7039, Vandœuvre-lès-Nancy Cedex, 54506, Franc
  • Pinel S; 2. Université de Lorraine, CRAN, UMR 7039, Campus Sciences, BP 70239, Vandœuvre-lès-Nancy Cedex, 54506, France; ; 3. CNRS, CRAN, UMR 7039, Vandœuvre-lès-Nancy Cedex, 54506, France;
  • Toussaint M; 2. Université de Lorraine, CRAN, UMR 7039, Campus Sciences, BP 70239, Vandœuvre-lès-Nancy Cedex, 54506, France; ; 3. CNRS, CRAN, UMR 7039, Vandœuvre-lès-Nancy Cedex, 54506, France;
  • Frochot C; 4. Université de Lorraine, LRGP, UMR 7274, 1 rue Grandville, Nancy, 54000, France; ; 5. CNRS, LRGP, UMR 7274, 1 rue Grandville, Nancy, 54000, France;
  • Chouikrat R; 4. Université de Lorraine, LRGP, UMR 7274, 1 rue Grandville, Nancy, 54000, France; ; 5. CNRS, LRGP, UMR 7274, 1 rue Grandville, Nancy, 54000, France;
  • Bastogne T; 2. Université de Lorraine, CRAN, UMR 7039, Campus Sciences, BP 70239, Vandœuvre-lès-Nancy Cedex, 54506, France; ; 3. CNRS, CRAN, UMR 7039, Vandœuvre-lès-Nancy Cedex, 54506, France; ; 6. Université de Lorraine, INRIA-BIGS & CRAN, BP 70239, Vandœuvre-lès-Nancy Cedex, 54506, France.
  • Barberi-Heyob M; 2. Université de Lorraine, CRAN, UMR 7039, Campus Sciences, BP 70239, Vandœuvre-lès-Nancy Cedex, 54506, France; ; 3. CNRS, CRAN, UMR 7039, Vandœuvre-lès-Nancy Cedex, 54506, France;
Theranostics ; 5(9): 1030-44, 2015.
Article em En | MEDLINE | ID: mdl-26155318
ABSTRACT
This review focuses on the radiosensitization strategies that use high-Z nanoparticles. It does not establish an exhaustive list of the works in this field but rather propose constructive criticisms pointing out critical factors that could improve the nano-radiation therapy. Whereas most reviews show the chemists and/or biologists points of view, the present analysis is also seen through the prism of the medical physicist. In particular, we described and evaluated the influence of X-rays energy spectra using a numerical analysis. We observed a lack of standardization in preclinical studies that could partially explain the low number of translation to clinical applications for this innovative therapeutic strategy. Pointing out the critical parameters of high-Z nanoparticles radiosensitization, this review is expected to contribute to a larger preclinical and clinical development.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiossensibilizantes / Radioterapia / Nanopartículas Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiossensibilizantes / Radioterapia / Nanopartículas Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article