Early postoperative management of heart transplant recipients with current ventricular assist device support in Japan: experience from a single center.
Matsumoto, Yu; Shibata, Sho C; Maeda, Akihiko; Yoshioka, Daisuke; Kamibayashi, Takahiko; Uchiyama, Akinori; Sawa, Yoshiki; Fujino, Yuji.
Afiliação
  • Matsumoto Y; Department of Anesthesiology and Intensive Care Medicine, Graduate School of Medicine, Osaka University, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Shibata SC; Department of Anesthesiology and Intensive Care Medicine, Graduate School of Medicine, Osaka University, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan. karlshibata@pain.med.osaka-u.ac.jp.
  • Maeda A; Department of Anesthesiology and Intensive Care Medicine, Graduate School of Medicine, Osaka University, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Yoshioka D; Department of Cardiovascular Surgery, Graduate School of Medicine, Osaka, Japan.
  • Kamibayashi T; Department of Anesthesiology and Intensive Care Medicine, Graduate School of Medicine, Osaka University, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Uchiyama A; Department of Anesthesiology and Intensive Care Medicine, Graduate School of Medicine, Osaka University, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Sawa Y; Department of Cardiovascular Surgery, Graduate School of Medicine, Osaka, Japan.
  • Fujino Y; Department of Anesthesiology and Intensive Care Medicine, Graduate School of Medicine, Osaka University, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
J Anesth ; 29(6): 868-73, 2015 Dec.
Article em En | MEDLINE | ID: mdl-26162779
ABSTRACT

PURPOSE:

This study reviews our experience with the perioperative management of heart transplant (HT) recipients and explores how prior ventricular assist device (VAD) support affects the requirements for postoperative mechanical ventilation and circulatory support. METHODS AND

RESULTS:

A retrospective database review was performed from 2007 to 2014. Early postoperative outcomes were compared between VAD and non-VAD groups. Forty-four patients were studied. The mean age was 38 ± 13 years, 30% were female, and 88% experienced non-ischemic heart failure. Forty patients (91%) required VAD support at the time of HT, with a mean duration of 864 ± 351 days. The median postoperative mechanical ventilation times in the VAD and non-VAD groups were 54 [95% confidence interval (CI) 42.9-297.3] and 15 (95% CI 4.8-30.0; p = 0.0199) hours, respectively. The VAD group experienced increased bleeding during the first 48 h after HT (6.7 ± 3.5 vs. 1.8 ± 0.75 l, p = 0.004). Mechanical circulatory support with intra-aortic balloon pumping or venoarterial extracorporeal membrane oxygenation was required in 30% of VAD group patients. Increased bleeding and primary graft failure were the main causes of prolonged mechanical ventilation.

CONCLUSIONS:

HT recipients with VAD support required longer mechanical ventilation periods and mechanical circulatory support in the postoperative period.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Respiração Artificial / Oxigenação por Membrana Extracorpórea / Coração Auxiliar / Transplante de Coração Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged País como assunto: Asia Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Respiração Artificial / Oxigenação por Membrana Extracorpórea / Coração Auxiliar / Transplante de Coração Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged País como assunto: Asia Idioma: En Ano de publicação: 2015 Tipo de documento: Article