Your browser doesn't support javascript.
loading
A new method for achieving compression in hindfoot arthrodesis.
Greisberg, Justin; Vosseller, J Turner; Ferry, Chris; Nash, Calvin; Gardner, Thomas R.
Afiliação
  • Greisberg J; Department of Orthopaedic Surgery, Columbia University Medical Center, 622 West 168th St, PH 11th floor, New York, NY, 10032, USA. jkg2101@columbia.edu.
  • Vosseller JT; Department of Orthopaedic Surgery, Columbia University Medical Center, 622 West 168th St, PH 11th floor, New York, NY, 10032, USA.
  • Ferry C; Department of Orthopaedic Surgery, Columbia University Medical Center, 622 West 168th St, PH 11th floor, New York, NY, 10032, USA.
  • Nash C; Department of Orthopaedic Surgery, Columbia University Medical Center, 622 West 168th St, PH 11th floor, New York, NY, 10032, USA.
  • Gardner TR; Department of Orthopaedic Surgery, Columbia University Medical Center, 622 West 168th St, PH 11th floor, New York, NY, 10032, USA.
Int Orthop ; 39(11): 2267-74, 2015 Nov.
Article em En | MEDLINE | ID: mdl-26202016
BACKGROUND: When performing hindfoot arthodeses, one goal of fixation is often to achieve compression across the joint. Traditional lag screws are applied eccentrically, providing compression more on the edge of the fusion. A new technique, using a post in one bone and a lag screw through the post to the other bone, may offer better compression across more of the joint. METHODS: There are three parts to this study comparing a post-and-screw construct to traditional lag screws. Synthetic bone models, representative of the talonavicular joint, were created and assessed for biomechanical measures of compression. Next, the post-and-screw construct was tested in cadavers, under conditions representing early weight bearing after arthrodesis surgery. Finally, 18 patients who had a talonavicular fusion with a post-and-screw construct with one surgeon were compared to the previous 18 patients fixed with traditional screws. RESULTS: In the synthetic bone model, the post-and-screw construct brought the centre of compression closer to the centre of the joint, suggesting compression was less eccentric. Neither traditional screws nor the post-and-screw construct were sufficiently strong to resist early weight bearing forces in cadaver specimens. In the clinical comparison, four patients had a painful nonunion when fixed with traditional screws, compared to none in the post-and-screw construct. CONCLUSIONS: A post-and-screw construct spreads the forces of compression more uniformly across an arthrodesis, even when placed eccentrically. Although not all the biomechanical measures were superior, the post-and-screw construct achieved higher levels of successful fusion in patients. This technology may offer improved outcomes in some clinical scenarios and deserves further study. LEVEL OF EVIDENCE: Level 3.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrodese / Articulações Tarsianas / Pé / Doenças do Pé Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrodese / Articulações Tarsianas / Pé / Doenças do Pé Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article