Your browser doesn't support javascript.
loading
Loop-mediated isothermal amplification for rapid molecular detection of Enterocytozoon bieneusi in faecal specimens.
Nur Su'aidah Nasarudin, Siti; Shazalina Zainudin, Nurul; Bernadus, Mekadina; Mohd Nawi, Azmawati; Hanafiah, Alfizah; Osman, Emelia.
Afiliação
  • Nur Su'aidah Nasarudin S; Department of Parasitology & Medical Entomology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latiff, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, Malaysia.
  • Shazalina Zainudin N; Department of Parasitology & Medical Entomology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latiff, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, Malaysia.
  • Bernadus M; Department of Parasitology & Medical Entomology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latiff, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, Malaysia.
  • Mohd Nawi A; Department of Public Health, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latiff, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, Malaysia.
  • Hanafiah A; Department of Medical Microbiology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latiff, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, Malaysia.
  • Osman E; Department of Parasitology & Medical Entomology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latiff, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, Malaysia.
J Med Microbiol ; 64(11): 1329-1334, 2015 Nov.
Article em En | MEDLINE | ID: mdl-26307076
ABSTRACT
A loop-mediated isothermal amplification (LAMP) assay was developed to detect Enterocytozoon bieneusi DNA for the first time from human faecal specimens. Four primers specific for Enterocytozoon bieneusi were designed corresponding to small subunit rRNA gene sequences and tested on 100 human faecal specimens. Thirty-nine of the faecal specimens (39%) were confirmed positive for Enterocytozoon bieneusi by LAMP compared with 33% by PCR and 32% by light microscopy. LAMP yielded 94% sensitivity and 88% specificity compared with microscopy (sensitivity 48%, specificity 76%). No significant differences in positive detection of Enterocytozoon bieneusi were found among the three methods (P>0.05). However, LAMP has shown a substantial agreement with PCR (κ = 0.78) and fair agreement was demonstrated between microscopy and PCR (κ = 0.25). In conclusion, the LAMP assay proved to be useful as a simplified, rapid, sensitive and specific alternative molecular screening tool in the diagnosis of Enterocytozoon bieneusi in faecal specimens
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Microsporidiose / Enterocytozoon / Técnicas de Amplificação de Ácido Nucleico / Fezes Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Microsporidiose / Enterocytozoon / Técnicas de Amplificação de Ácido Nucleico / Fezes Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article