Your browser doesn't support javascript.
loading
[Clinical Experience of Beating Heart Atrial Septostomy Using a Device for Coronary Artery Anastomosis Site Creator].
Takahashi, Goro; Sai, Sadahiro; Konishi, Akinobu.
Afiliação
  • Takahashi G; Department of Cardiovascular Surgery, Sendai Medical Center, Sendai, Japan.
Kyobu Geka ; 68(10): 822-5, 2015 Sep.
Article em Ja | MEDLINE | ID: mdl-26329624
ABSTRACT

BACKGROUND:

Intra-atrial communication was mandatory for several congenital cardiac diseases, such as pulmonary atresia with intact ventricular septum (PA/IVS), and either sided aortoventricular valve atresia. We assessed whether the new methods of atrial septal defect(ASD)creation was effective.

METHODS:

We experienced 4 cases of the surgical atrial septostomy performed under on-pump beating. We used a new device, a circular punch out defect creator.

RESULTS:

All cases were alive. The mean ASD diameter was enlarged from 4.37 mm to 5.55 mm and the mean ASD shunt flow was significantly decreased from 1.47 m/s to 1.11 m/s.

CONCLUSIONS:

We performed the surgical atrial septostomy using an aortic puncher under beating heart effectively and safely.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Ponte de Artéria Coronária sem Circulação Extracorpórea / Septo Interatrial Limite: Humans / Infant Idioma: Ja Ano de publicação: 2015 Tipo de documento: Article