Your browser doesn't support javascript.
loading
Determination of Drugs in Plasma Samples by High-Performance Liquid Chromatography-Tandem Mass Spectrometry for Therapeutic Drug Monitoring of Schizophrenic Patients.
Domingues, Diego Soares; Pinto, Mônia Aparecida Lemos; de Souza, Israel Donizeti; Hallak, Jaime Eduardo Cecilio; Crippa, José Alexandre de Souza; Queiroz, Maria Eugênia Costa.
Afiliação
  • Domingues DS; Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, São Paulo, Brazil.
  • Pinto MA; Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo, São Paulo, Brazil.
  • de Souza ID; Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, São Paulo, Brazil.
  • Hallak JE; Department of Neuroscience and Behavior, Ribeirão Preto Medical School, University of São Paulo, São Paulo, Brazil.
  • Crippa JA; Department of Neuroscience and Behavior, Ribeirão Preto Medical School, University of São Paulo, São Paulo, Brazil.
  • Queiroz ME; Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, São Paulo, Brazil mariaeqn@ffclrp.usp.br.
J Anal Toxicol ; 40(1): 28-36, 2016.
Article em En | MEDLINE | ID: mdl-26333987
ABSTRACT
This work describes the development of a simple, sensitive and selective method based on high-performance liquid chromatography coupled to tandem mass spectrometry (LC-MS-MS) to determine antipsychotics (olanzapine, quetiapine, clozapine, haloperidol and chlorpromazine) along with antidepressants (mirtazapine, paroxetine, citalopram, sertraline, imipramine, clomipramine and fluoxetine), anticonvulsants (carbamazepine and lamotrigine) and anxiolytics (diazepam and clonazepam) in plasma samples obtained from schizophrenic patients. The samples were prepared by protein precipitation. The target drugs were separated on an XSelect SCH C18 column (100 mm × 2.1 mm × 2.5 µm) within 8.0 min by means of gradient elution. The drugs were then detected on a quadrupole tandem mass spectrometer equipped with an electrospray ionization source, operating in the multiple reactions monitoring mode and in the positive ionization mode. The LC-MS-MS method was linear range from subtherapeutic to toxic concentrations with lower limit of quantification values ranged from 0.2 to 5.0 ng mL(-1), precision with coefficient of variation values lower than 12%, and accuracy ranged from 90 to 108%. The developed method enabled successful analysis of the target drugs in plasma samples obtained from 51 schizophrenic patients. Therapeutic drug monitoring revealed that many of the evaluated schizophrenic patients presented altered plasma concentrations of the analyzed drugs. These altered concentrations resulted from pharmacokinetic interactions among the medications prescribed to treat schizophrenia.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Psicotrópicos / Esquizofrenia / Cromatografia Líquida de Alta Pressão / Monitoramento de Medicamentos / Espectrometria de Massas em Tandem / Anticonvulsivantes Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Psicotrópicos / Esquizofrenia / Cromatografia Líquida de Alta Pressão / Monitoramento de Medicamentos / Espectrometria de Massas em Tandem / Anticonvulsivantes Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article