A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip.
Balakrishnan, S R; Hashim, U; Gopinath, Subash C B; Poopalan, P; Ramayya, H R; Iqbal Omar, M; Haarindraprasad, R; Veeradasan, P.
Afiliação
  • Balakrishnan SR; Biomedical Nano Diagnostics Research Group, Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, Malaysia.
  • Hashim U; Biomedical Nano Diagnostics Research Group, Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, Malaysia.
  • Gopinath SC; Biomedical Nano Diagnostics Research Group, Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, Malaysia.
  • Poopalan P; School of Microelectronic Engineering, University Malaysia Perlis (UniMAP), Kuala Perlis, Perlis, Malaysia.
  • Ramayya HR; Department of Obstetrics and Gynaecology, Hospital Tuanku Fauziah, Kangar, Perlis, Malaysia.
  • Iqbal Omar M; University Health Centre, Universiti Malaysia Perlis (UniMAP), Kuala Perlis, Perlis, Malaysia.
  • Haarindraprasad R; Biomedical Nano Diagnostics Research Group, Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, Malaysia.
  • Veeradasan P; Biomedical Nano Diagnostics Research Group, Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, Malaysia.
PLoS One ; 10(9): e0137891, 2015.
Article em En | MEDLINE | ID: mdl-26368287
ABSTRACT
Human chorionic gonadotropin (hCG), a glycoprotein hormone secreted from the placenta, is a key molecule that indicates pregnancy. Here, we have designed a cost-effective, label-free, in situ point-of-care (POC) immunosensor to estimate hCG using a cuneated 25 nm polysilicon nanogap electrode. A tiny chip with the dimensions of 20.5 × 12.5 mm was fabricated using conventional lithography and size expansion techniques. Furthermore, the sensing surface was functionalized by (3-aminopropyl)triethoxysilane and quantitatively measured the variations in hCG levels from clinically obtained human urine samples. The dielectric properties of the present sensor are shown with a capacitance above 40 nF for samples from pregnant women; it was lower with samples from non-pregnant women. Furthermore, it has been proven that our sensor has a wide linear range of detection, as a sensitivity of 835.88 µA mIU(-1) ml(-2) cm(-2) was attained, and the detection limit was 0.28 mIU/ml (27.78 pg/ml). The dissociation constant Kd of the specific antigen binding to the anti-hCG was calculated as 2.23 ± 0.66 mIU, and the maximum number of binding sites per antigen was Bmax = 22.54 ± 1.46 mIU. The sensing system shown here, with a narrow nanogap, is suitable for high-throughput POC diagnosis, and a single injection can obtain triplicate data or parallel analyses of different targets.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Gravidez / Técnicas Biossensoriais / Sistemas Automatizados de Assistência Junto ao Leito / Dispositivos Lab-On-A-Chip / Gonadotropina Coriônica Limite: Adult / Female / Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Gravidez / Técnicas Biossensoriais / Sistemas Automatizados de Assistência Junto ao Leito / Dispositivos Lab-On-A-Chip / Gonadotropina Coriônica Limite: Adult / Female / Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article