Biological efficacy and toxic effect of emergency water disinfection process based on advanced oxidation technology.
Tian, Yiping; Yuan, Xiaoli; Xu, Shujing; Li, Rihong; Zhou, Xinying; Zhang, Zhitao.
Afiliação
  • Tian Y; Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China.
  • Yuan X; Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China.
  • Xu S; Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China.
  • Li R; Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China.
  • Zhou X; Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China.
  • Zhang Z; Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China. newzhangzhitao@163.com.
Ecotoxicology ; 24(10): 2141-50, 2015 Dec.
Article em En | MEDLINE | ID: mdl-26427371
ABSTRACT
An innovative and removable water treatment system consisted of strong electric field discharge and hydrodynamic cavitation based on advanced oxidation technologies was developed for reactive free radicals producing and waterborne pathogens eliminating in the present study. The biological efficacy and toxic effects of this advanced oxidation system were evaluated during water disinfection treatments. Bench tests were carried out with synthetic microbial-contaminated water, as well as source water in rainy season from a reservoir of Dalian city (Liaoning Province, China). Results showed that high inactivation efficiency of Escherichia coli (>5 log) could be obtained for synthetic contaminated water at a low concentration (0.5-0.7 mg L(-1)) of total oxidants in 3-10 s. The numbers of wild total bacteria (108 × 10(3) CFU mL(-1)) and total coliforms (260 × 10(2) MPN 100 mL(-1)) in source water greatly reduced to 50 and 0 CFU mL(-1) respectively after treated by the advanced oxidation system, which meet the microbiological standards of drinking water, and especially that the inactivation efficiency of total coliforms could reach 100%. Meanwhile, source water qualities were greatly improved during the disinfection processes. The values of UV254 in particular were significantly reduced (60-80%) by reactive free radicals. Moreover, the concentrations of possible disinfection by-products (formaldehyde and bromide) in treated water were lower than detection limits, indicating that there was no harmful effect on water after the treatments. These investigations are helpful for the ecotoxicological studies of advanced oxidation system in the treatments of chemical polluted water or waste water. The findings of this work suggest that the developed water treatment system is ideal in the acute phases of emergencies, which also could offer additional advantages over a wide range of applications in water pollution control.