Your browser doesn't support javascript.
loading
High sensitivity flow cytometry of membrane vesicles.
Stoner, Samuel A; Duggan, Erika; Condello, Danilo; Guerrero, Abraham; Turk, James R; Narayanan, Padma K; Nolan, John P.
Afiliação
  • Stoner SA; La Jolla Bioengineering Institute, La Jolla, California, 92037.
  • Duggan E; La Jolla Bioengineering Institute, La Jolla, California, 92037.
  • Condello D; Scintillon Institute, San Diego, California, 92121.
  • Guerrero A; La Jolla Bioengineering Institute, La Jolla, California, 92037.
  • Turk JR; Scintillon Institute, San Diego, California, 92121.
  • Narayanan PK; Comparative Biology and Safety Sciences, Amgen Inc, Seattle, Washington.
  • Nolan JP; Comparative Biology and Safety Sciences, Amgen Inc, Seattle, Washington.
Cytometry A ; 89(2): 196-206, 2016 Feb.
Article em En | MEDLINE | ID: mdl-26484737
Extracellular vesicles (EVs) are attracting attention as vehicles for inter-cellular signaling that may have value as diagnostic or therapeutic targets. EVs are released by many cell types and by different mechanisms, resulting in phenotypic heterogeneity that makes them a challenge to study. Flow cytometry is a popular tool for characterizing heterogeneous mixtures of particles such as cell types within blood, but the small size of EVs makes them difficult to measure using conventional flow cytometry. To address this limitation, a high sensitivity flow cytometer was constructed and EV measurement approaches that allowed them to enumerate and estimate the size of individual EVs, as well as measure the presence of surface markers to identify phenotypic subsets of EVs. Several fluorescent membrane probes were evaluated and it was found that the voltage sensing dye di-8-ANEPPS could produce vesicle fluorescence in proportion to vesicle surface area, allowing for accurate measurements of EV number and size. Fluorescence-labeled annexin V and anti-CD61 antibody was used to measure the abundance of these surface markers on EVs in rat plasma. It was shown that treatment of platelet rich plasma with calcium ionophore resulted in an increase in the fraction of annexin V and CD61-positive EVs. Vesicle flow cytometry using fluorescence-based detection of EVs has the potential to realize the potential of cell-derived membrane vesicles as functional biomarkers for a variety of applications.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Citometria de Fluxo / Vesículas Extracelulares Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Citometria de Fluxo / Vesículas Extracelulares Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article