Your browser doesn't support javascript.
loading
Intraprocedural Safety and Technical Success of the MVP Micro Vascular Plug for Embolization of Pulmonary Arteriovenous Malformations.
Conrad, Miles B; Ishaque, Brandon M; Surman, Andrew M; Kerlan, Robert K; Hope, Michael D; Dickey, Melissa A; Hetts, Steven W; Wilson, Mark W.
Afiliação
  • Conrad MB; Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143. Electronic address: Miles.Conrad@ucsf.edu.
  • Ishaque BM; Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143.
  • Surman AM; Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143.
  • Kerlan RK; Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143.
  • Hope MD; Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143.
  • Dickey MA; Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143.
  • Hetts SW; Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143.
  • Wilson MW; Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143.
J Vasc Interv Radiol ; 26(11): 1735-9, 2015 Nov.
Article em En | MEDLINE | ID: mdl-26505940
ABSTRACT
This case series describes early experience, intraprocedural safety, and technical success of the MVP Micro Vascular Plug (MVP; Covidien, Irvine, California) for embolization of 20 pulmonary arteriovenous malformations (PAVMs) using 23 plugs in seven patients with hereditary hemorrhagic telangiectasia. There was no device migration, and all devices were successfully detached electrolytically. Immediate cessation of flow through the feeding artery was achieved in 21 of 23 (91%) deployments. There was one minor complication. This series demonstrates the MVP to be safe and technically successful in the treatment of PAVMs.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artéria Pulmonar / Veias Pulmonares / Prótese Vascular / Fístula Arteriovenosa / Oclusão com Balão / Embolização Terapêutica Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artéria Pulmonar / Veias Pulmonares / Prótese Vascular / Fístula Arteriovenosa / Oclusão com Balão / Embolização Terapêutica Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article