Standard B-Mode Ultrasound Measures Local Carotid Artery Characteristics as Reliably as Radiofrequency Phase Tracking in Symptomatic Carotid Artery Patients.
Steinbuch, Jeire; Hoeks, Arnold P G; Hermeling, Evelien; Truijman, Martine T B; Schreuder, Floris H B M; Mess, Werner H.
Afiliação
  • Steinbuch J; Department of Biomedical Engineering, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, the Netherlands.
  • Hoeks AP; Department of Biomedical Engineering, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, the Netherlands.
  • Hermeling E; Department of Radiology, Maastricht University Medical Center, Maastricht, the Netherlands.
  • Truijman MT; Department of Radiology, Maastricht University Medical Center, Maastricht, the Netherlands; Department of Clinical Neurophysiology, Maastricht University Medical Center, Maastricht, the Netherlands; Department of Neurology, Maastricht University Medical Center, Maastricht, the Netherlands.
  • Schreuder FH; Department of Radiology, Maastricht University Medical Center, Maastricht, the Netherlands; Department of Clinical Neurophysiology, Maastricht University Medical Center, Maastricht, the Netherlands; Department of Neurology, Maastricht University Medical Center, Maastricht, the Netherlands.
  • Mess WH; Department of Clinical Neurophysiology, Maastricht University Medical Center, Maastricht, the Netherlands. Electronic address: werner.mess@mumc.nl.
Ultrasound Med Biol ; 42(2): 586-95, 2016 Feb.
Article em En | MEDLINE | ID: mdl-26525651
ABSTRACT
Local arterial stiffness can be assessed with high accuracy and precision by measuring arterial distension on the basis of phase tracking of radiofrequency ultrasound signals acquired at a high frame rate. However, in clinical practice, B-mode ultrasound registrations are made at a low frame rate (20-50 Hz). We compared the accuracy and intra-subject precision of edge tracking and phase tracking distension in symptomatic carotid artery patients. B-mode ultrasound recordings (40 mm, 37 fps) and radiofrequency recordings (31 lines covering 29 mm, 300 fps) were acquired from the left common carotid artery of 30 patients (aged 45-88 y) with recent cerebrovascular events. To extract the distension, semi-automatic echo edge and phase tracking algorithms were applied to B-mode and radiofrequency recordings, respectively. Both methods exhibited a similar intra-subject precision for distension (standard deviation = 44 µm and 47 µm, p = 0.66) and mean distension (difference -6 ± 69 µm, p = 0.67). Intra-subject distension inhomogeneity tends to be larger for edge tracking (difference 15 ± 35 µm, p = 0.04). Standard B-mode scanners are suitable for measuring local artery characteristics in symptomatic carotid artery patients with good precision and accuracy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Artérias Carótidas / Doenças das Artérias Carótidas / Rigidez Vascular Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Artérias Carótidas / Doenças das Artérias Carótidas / Rigidez Vascular Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2016 Tipo de documento: Article