Your browser doesn't support javascript.
loading
Point-of-Care Phalangeal Bone Mineral Density Measurement Can Reduce the Need of Dual-Energy X-Ray Absorptiometry Scanning in Danish Women at Risk of Fracture.
Holmberg, Teresa; Bech, Mickael; Gram, Jeppe; Hermann, Anne Pernille; Rubin, Katrine Hass; Brixen, Kim.
Afiliação
  • Holmberg T; National Institute of Public Health, University of Southern Denmark, Øster Farimagsgade 5A, 2, 1399, Copenhagen K, Denmark. tho@niph.dk.
  • Bech M; KORA, the Danish Institute for Local and Regional Government Research, Copenhagen, Denmark.
  • Gram J; Department of Endocrinology, Hospital of Southwest Denmark, Esbjerg, Denmark.
  • Hermann AP; Department of Endocrinology, Odense University Hospital, Odense, Denmark.
  • Rubin KH; Odense Patient Data Explorative Network (OPEN), Institute of Clinical Research, University of Southern Denmark, Odense M, Denmark.
  • Brixen K; Department of Endocrinology, Odense University Hospital, Odense, Denmark.
Calcif Tissue Int ; 98(3): 244-52, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26590810
ABSTRACT
Identifying persons with a high risk of osteoporotic fractures remains a challenge. DXA uptake in women with elevated risk of osteoporosis seems to be depending on distance to scanning facilities. This study aimed to investigate the ability of a small portable scanner in identifying women with reduced bone mineral density (BMD), and to define triage thresholds for pre-selection. Total hip and lumbar spine BMD was measured by dual-energy X-ray absorptiometry and phalangeal BMD by radiographic absorptiometry in 121 Danish women with intermediate or high 10-year fracture probability (aged 61-81 years). Correlation between the two methods was estimated using correlation coefficient (r) and Bland-Altman plots. A moderate correlation between phalangeal BMD versus total hip (r = 0.47) and lumbar spine (r = 0.51), and an AUC on 0.80 was found. The mean difference between phalangeal T score and total hip T score/lumbar spine T score was low, and ranged from -0.26 SD to -0.31 SD depending on site and reference database used for calculation of T scores, but, large variation was seen at an individual level. When applying a triage approach approx. one-third of all DXA scan could be avoided and only 6 % of women in the low-risk group would be false negatives.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Absorciometria de Fóton / Densidade Óssea / Falanges dos Dedos da Mão / Fraturas por Osteoporose / Testes Imediatos Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Absorciometria de Fóton / Densidade Óssea / Falanges dos Dedos da Mão / Fraturas por Osteoporose / Testes Imediatos Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2016 Tipo de documento: Article