Your browser doesn't support javascript.
loading
Development of an Assay for Methotrexate and Its Metabolites 7-Hydroxy Methotrexate and DAMPA in Serum by LC-MS/MS.
Schofield, Ryan C; Ramanathan, Lakshmi V; Murata, Kazunori; Fleisher, Martin; Pessin, Melissa S; Carlow, Dean C.
Afiliação
  • Schofield RC; Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
  • Ramanathan LV; Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
  • Murata K; Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
  • Fleisher M; Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
  • Pessin MS; Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
  • Carlow DC; Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA. carlowd@mskcc.org.
Methods Mol Biol ; 1383: 213-22, 2016.
Article em En | MEDLINE | ID: mdl-26660190
ABSTRACT
Methotrexate (MTX) is a folic acid antagonist that is widely used as an immunosuppressant and chemotherapeutic agent. After high-dose administration of MTX serum levels must be monitored to determine when to administer leucovorin, a folic acid analog that bypasses the enzyme inhibition caused by MTX and reverses its toxicity. We describe a rapid and simple turbulent flow liquid chromatography (TFLC) method implementing positive heated electrospray ionization (HESI) for the accurate and precise determination of MTX, 7-hydroxymethotrexate (7-OH MTX), and 4-amino-4-deoxy-N(10)-methylpteroic acid (DAMPA) concentrations in serum. MTX is isolated from serum samples (100 µL) after protein precipitation with a methanolic solution containing internal standard (MTX-D3) followed by centrifugation. The supernatant is injected into the turbulent flow liquid chromatography which is followed by electrospray positive ionization tandem mass spectrometry (TFLC-ESI-MS/MS) and quantified using a six-point calibration curve. For MTX, 7-OH MTX, and DAMPA the assays were linear from 20 to 1000 nmol/L. Dilutions of 10-, 100-, and 1000-fold were validated giving a clinically reportable range of 20 to 1.0 × 10(6) nmol/L. Within-day and between-day precisions at concentrations spanning the analytical measurement ranges were less than 10 % for all three analytes.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Metotrexato / Espectrometria de Massas em Tandem / Imunossupressores / Antimetabólitos Antineoplásicos Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Metotrexato / Espectrometria de Massas em Tandem / Imunossupressores / Antimetabólitos Antineoplásicos Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article