Effect of degree of conversion on in vivo biocompatibility of flowable resin used for bioprotection of mini-implants.
Lacerda-Santos, Rogério; de Meneses, Izaura Helena Chaves; Sampaio, Gêisa Aiane de Morais; Pithon, Matheus Melo; Alves, Polliana Muniz.
Afiliação
  • Lacerda-Santos R; a Professor, Degree Program in Dentistry, Federal University of Campina Grande, Patos, Brazil.
  • de Meneses IH; b Master's Student, Graduate Program in Dentistry, Federal University of Paraíba, João Pessoa, Brazil.
  • Sampaio GA; b Master's Student, Graduate Program in Dentistry, Federal University of Paraíba, João Pessoa, Brazil.
  • Pithon MM; c Professor, Degree Program in Dentistry, State University of Southwest Bahia, Jequié, Brazil.
  • Alves PM; d Professor, Graduate Program in Dentistry, State University of Paraíba, Campina Grande, Brazil.
Angle Orthod ; 86(1): 157-63, 2016 Jan.
Article em En | MEDLINE | ID: mdl-26716818
ABSTRACT

OBJECTIVE:

To test the hypothesis that there is no difference between the biocompatibility and degree of monomer conversion of flowable resins used as bioprotective materials of orthodontic mini-implants. MATERIALS AND

METHODS:

Forty-eight male Wistar rats were divided into four groups (n  =  12). Group Control (polyethylene), Group Wave, Group Top Comfort, and Group Filtek. The animals were sacrificed after time intervals of 7, 15, and 30 days and tissues were analyzed under optical microscopy for inflammatory infiltrate, edema, necrosis, granulation tissue, multinucleated giant cells, and collagen formation. The degree of conversion was evaluated by the Fourier method. Biocompatibility and degree of conversion were evaluated by the Kruskal-Wallis and Dunn tests, and analysis of variance and the Tukey test, respectively (P < .05).

RESULTS:

An intense inflammatory infiltrate was observed on the seventh day, with Groups Top Comfort and Filtek differing statistically from Group Control (P  =  .016). Edema, necrosis, granulation tissue, and giant cells showed greater expressiveness at 7 days, without statistical difference between them (P > .05). For the presence of collagen fibers, Group Top Comfort was shown to differ statistically from Group Control (P  =  .037) at 15 days and from Groups Filtek and Control (P  =  .008) at 30 days. Monomer conversion ranged from 62.3% in Group Top Comfort at 7 days to 79.1% in Group Filtek at 30 days.

CONCLUSIONS:

The hypothesis was rejected. The resin Top Comfort demonstrated lower tissue repair capacity with a lower number of collagen fibers compared with Filtek and Wave resins. The resin Top Comfort showed the lowest conversion values during the experiment.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Teste de Materiais / Implantes Dentários / Resinas Compostas Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Teste de Materiais / Implantes Dentários / Resinas Compostas Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article