Your browser doesn't support javascript.
loading
Accuracy of sonographic fetal weight estimation: influence of the scan-to-delivery interval in combination with the applied weight estimation formula.
Faschingbauer, F; Raabe, E; Heimrich, J; Faschingbauer, C; Schmid, M; Mayr, A; Schild, R L; Beckmann, M W; Kehl, S.
Afiliação
  • Faschingbauer F; Department of Obstetrics and Gynecology, Erlangen University Hospital, Universitätsstrasse 21-23, 91054, Erlangen, Germany. florian.faschingbauer@uk-erlangen.de.
  • Raabe E; Department of Obstetrics and Gynecology, Erlangen University Hospital, Universitätsstrasse 21-23, 91054, Erlangen, Germany.
  • Heimrich J; Department of Obstetrics and Gynecology, Erlangen University Hospital, Universitätsstrasse 21-23, 91054, Erlangen, Germany.
  • Faschingbauer C; Department of Obstetrics and Gynecology, Erlangen University Hospital, Universitätsstrasse 21-23, 91054, Erlangen, Germany.
  • Schmid M; Department of Medical Informatics, Biometry and Epidemiology, Rheinische Friedrich-Wilhelms-University Bonn, Bonn, Germany.
  • Mayr A; Department of Medical Informatics, Biometry and Epidemiology, University of Erlangen-Nuremberg, Erlangen, Germany.
  • Schild RL; Department of Obstetrics and Perinatal Medicine, DDH Frauenkliniken, Hanover, Germany.
  • Beckmann MW; Department of Obstetrics and Gynecology, Erlangen University Hospital, Universitätsstrasse 21-23, 91054, Erlangen, Germany.
  • Kehl S; Department of Obstetrics and Gynecology, Erlangen University Hospital, Universitätsstrasse 21-23, 91054, Erlangen, Germany.
Arch Gynecol Obstet ; 294(3): 487-93, 2016 09.
Article em En | MEDLINE | ID: mdl-26742730
INTRODUCTION: To evaluate the influence of the time interval between examination and delivery on the accuracy of sonographic fetal weight estimation (WE). MATERIALS AND METHODS: 8723 singleton pregnancies were included in this retrospective cohort study. Fetuses were divided into eight groups with regard to the time interval between estimation and delivery (group 1: 0 days; group 2: 1-3 days; group 3: 4-7 days; group 4: 8-14 days; group 5: 15-21 days; group 6: 22-28 days; group 7: 29-35 days; group 8: 36-42 days). The accuracy of WE was compared between the different time interval groups and five commonly used formulas using means of percentage errors (MPE), medians of absolute percentage errors, and proportions of estimates within 10 % of actual birth weight. RESULTS: In group one, the Hadlock I and Warsof formula showed a systematic underestimation of fetal weight (negative MPEs). No systematic error was found with the Hadlock II formula and the equations of Merz and Shepard showed a systematic overestimation (positive MPEs). MPE values of the Hadlock I, II and Warsof formulas were closest to zero in WEs of group two. From group three to six, MPE values decreased continuously. With the Merz and Shepard equations MPEs were closest to zero in group four. DISCUSSION: The best accuracy of sonographic WE with most of the commonly used equations is achieved within a scan-to-delivery interval of 1 week.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Peso ao Nascer / Ultrassonografia Pré-Natal / Peso Fetal Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Peso ao Nascer / Ultrassonografia Pré-Natal / Peso Fetal Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Ano de publicação: 2016 Tipo de documento: Article