Your browser doesn't support javascript.
loading
Clinical evaluations of cast gold alloy, machinable zirconia, and semiprecious alloy crowns: A multicenter study.
Park, Ji-Man; Hong, Yong-Shin; Park, Eun-Jin; Heo, Seong-Joo; Oh, Namsik.
Afiliação
  • Park JM; Clinical Associate Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University Gwanak Dental Hospital, Seoul, Korea.
  • Hong YS; Former resident, Department of Prosthodontics, School of Medicine, Ewha Womans University, Seoul, Korea.
  • Park EJ; Professor, Department of Prosthodontics, School of Medicine, Ewha Womans University, Seoul, Korea.
  • Heo SJ; Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University, Seoul, Korea.
  • Oh N; Professor, Department of Dentistry, School of Medicine, Inha University, Incheon, Korea. Electronic address: onsdo@inha.ac.kr.
J Prosthet Dent ; 115(6): 684-91, 2016 Jun.
Article em En | MEDLINE | ID: mdl-26794694
ABSTRACT
STATEMENT OF

PROBLEM:

Few studies have compared the marginal and internal fits of crowns fabricated from machinable palladium-silver-indium (Pd-Ag-In) semiprecious metal alloy.

PURPOSE:

The purpose of this clinical study was to evaluate and compare the marginal and internal fits of machined Pd-Ag-In alloy, zirconia, and cast gold crowns. MATERIAL AND

METHODS:

A prospective clinical trial was performed on 35 participants and 52 abutment teeth at 2 centers. Individuals requiring prosthetic restorations were treated with gold alloy or zirconia crowns (2 control groups) or Pd-Ag-In alloy crowns (experimental group). A replica technique was used to evaluate the marginal and internal fits. The buccolingual and mesiodistal cross-sections were measured, and a noninferiority comparison was conducted.

RESULTS:

The mean marginal gaps were 68.2 µm for the gold crowns, 75.4 µm for the zirconia crowns, and 76.9 µm for the Pd-Ag-In alloy crowns. In the 5 cross-sections other than the distal cross-section, the 2-sided 95% confidence limits for the differences between the Pd-Ag-In alloy crowns and the 2 control groups were not larger than the 25-µm noninferiority margin. The control groups displayed smaller internal gaps in the line angle and occlusal spaces compared with the Pd-Ag-In crown group.

CONCLUSION:

The marginal gaps of machinable Pd-Ag-In alloy crowns did not meet the noninferiority criterion in the distal margin compared with zirconia and gold alloy crowns. Nonetheless, all 3 crowns had clinically applicable precision.
Assuntos

Texto completo: 1 Eixos temáticos: Pesquisa_clinica Base de dados: MEDLINE Assunto principal: Zircônio / Coroas / Ligas Dentárias / Ligas de Ouro Tipo de estudo: Clinical_trials Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Eixos temáticos: Pesquisa_clinica Base de dados: MEDLINE Assunto principal: Zircônio / Coroas / Ligas Dentárias / Ligas de Ouro Tipo de estudo: Clinical_trials Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article