Your browser doesn't support javascript.
loading
In vivo rectal wall measurements during HDR prostate brachytherapy with MOSkin dosimeters integrated on a trans-rectal US probe: Comparison with planned and reconstructed doses.
Carrara, Mauro; Tenconi, Chiara; Rossi, Giulio; Borroni, Marta; Cerrotta, Annamaria; Grisotto, Simone; Cusumano, Davide; Pappalardi, Brigida; Cutajar, Dean; Petasecca, Marco; Lerch, Michael; Gambarini, Grazia; Fallai, Carlo; Rosenfeld, Anatoly; Pignoli, Emanuele.
Afiliação
  • Carrara M; Medical Physics Unit, Dept. of Diagnostic Imaging and Radiotherapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy; Prostate Cancer Program, Scientific Director's Office, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy. Electronic address: mauro.carrara@istitutotumori.mi.i
  • Tenconi C; Medical Physics Unit, Dept. of Diagnostic Imaging and Radiotherapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.
  • Rossi G; Medical Physics Unit, Dept. of Diagnostic Imaging and Radiotherapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.
  • Borroni M; Medical Physics Unit, Dept. of Diagnostic Imaging and Radiotherapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy; Prostate Cancer Program, Scientific Director's Office, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.
  • Cerrotta A; Prostate Cancer Program, Scientific Director's Office, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy; Radiation Oncology 2 Unit, Dept. of Diagnostic Imaging and Radiotherapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.
  • Grisotto S; Medical Physics Unit, Dept. of Diagnostic Imaging and Radiotherapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.
  • Cusumano D; Medical Physics Unit, Dept. of Diagnostic Imaging and Radiotherapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.
  • Pappalardi B; Radiation Oncology 2 Unit, Dept. of Diagnostic Imaging and Radiotherapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.
  • Cutajar D; Centre for Medical Radiation Physics, University of Wollongong, Australia.
  • Petasecca M; Centre for Medical Radiation Physics, University of Wollongong, Australia.
  • Lerch M; Centre for Medical Radiation Physics, University of Wollongong, Australia.
  • Gambarini G; National Institute of Nuclear Physics INFN, Milan, Italy.
  • Fallai C; Prostate Cancer Program, Scientific Director's Office, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy; Radiation Oncology 2 Unit, Dept. of Diagnostic Imaging and Radiotherapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.
  • Rosenfeld A; Centre for Medical Radiation Physics, University of Wollongong, Australia.
  • Pignoli E; Medical Physics Unit, Dept. of Diagnostic Imaging and Radiotherapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy; Prostate Cancer Program, Scientific Director's Office, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.
Radiother Oncol ; 118(1): 148-53, 2016 Jan.
Article em En | MEDLINE | ID: mdl-26796593
ABSTRACT
BACKGROUND AND

PURPOSE:

To study if MOSkin detectors coupled to a trans-rectal ultrasound (TRUS) probe may be used for in vivo dosimetry on the rectal wall surface during US-based HDR prostate brachytherapy and to quantify possible discrepancies between planned and delivered doses. MATERIALS AND

METHODS:

MOSkins are a specific type of MOSFET dosimeter optimized to measure dose in steep dose gradients on interfaces. Two MOSkins were assembled on a TRUS probe used for on-line treatment planning. Measurements of the dose to the rectal wall were performed over 18 treatment sessions and compared to the doses calculated on the pre-treatment plan (DPRE) and reconstructed on post-treatment images (DPOST).

RESULTS:

Averages of the absolute differences between MOSkin readings and DPRE, MOSkin readings and DPOST and DPRE and DPOST were 6.7 ± 5.1%, 3.6 ± 1.9% and 6.3 ± 4.7%, respectively. Agreement between measurements and DPOST was significantly better than between measurements and DPRE (p=0.002) and DPRE and DPOST (p=0.004). Discrepancy between DPOST and DPRE correlated with the time required for treatment planning.

CONCLUSION:

MOSkin dosimeters integrated to the TRUS probe proved to be an accurate instrument for measuring the dose delivered to the rectal wall in HDR prostate brachytherapy. The delivered doses may differ significantly from those calculated in the treatment plan.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Reto / Planejamento da Radioterapia Assistida por Computador / Braquiterapia / Ultrassonografia de Intervenção Limite: Aged / Humans / Male Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Reto / Planejamento da Radioterapia Assistida por Computador / Braquiterapia / Ultrassonografia de Intervenção Limite: Aged / Humans / Male Idioma: En Ano de publicação: 2016 Tipo de documento: Article