Performance of the New Aptima HCV Quant Dx Assay in Comparison to the Cobas TaqMan HCV2 Test for Use with the High Pure System in Detection and Quantification of Hepatitis C Virus RNA in Plasma or Serum.
Schalasta, Gunnar; Speicher, Andrea; Börner, Anna; Enders, Martin.
Afiliação
  • Schalasta G; Prof. Gisela Enders & Kollegen MVZ GbR, Stuttgart, Germany schalasta@labor-enders.de.
  • Speicher A; Prof. Gisela Enders & Kollegen MVZ GbR, Stuttgart, Germany.
  • Börner A; Prof. Gisela Enders & Kollegen MVZ GbR, Stuttgart, Germany.
  • Enders M; Prof. Gisela Enders & Kollegen MVZ GbR, Stuttgart, Germany.
J Clin Microbiol ; 54(4): 1101-7, 2016 Apr.
Article em En | MEDLINE | ID: mdl-26865682
Quantitating the level of hepatitis C virus (HCV) RNA is the standard of care for monitoring HCV-infected patients during treatment. The performances of commercially available assays differ for precision, limit of detection, and limit of quantitation (LOQ). Here, we compare the performance of the Hologic Aptima HCV Quant Dx assay (Aptima) to that of the Roche Cobas TaqMan HCV test, version 2.0, using the High Pure system (HPS/CTM), considered a reference assay since it has been used in trials defining clinical decision points in patient care. The assays' performance characteristics were assessed using HCV RNA reference panels and plasma/serum from chronically HCV-infected patients. The agreement between the assays for the 3 reference panels was good, with a difference in quantitation values of <0.5 log. High concordance was demonstrated between the assays for 245 clinical samples (kappa = 0.80; 95% confidence interval [CI], 0.720 to 0.881); however, Aptima detected and/or quantitated 20 samples that HPS/CTM did not detect, while Aptima did not detect 1 sample that was quantitated by HPS/CTM. For the 165 samples quantitated by both assays, the values were highly correlated (R= 0.98;P< 0.0001). The linearity of quantitation from concentrations of 1.4 to 6 log was excellent for both assays for all HCV genotypes (GT) tested (GT 1a, 1b, 2b, and 3a) (R(2)> 0.99). The assays had similar levels of total and intra-assay variability across all genotypes at concentrations from 1,000 to 25 IU/ml. Aptima had a greater analytical sensitivity, quantitating more than 50% of replicates at 25-IU/ml target. Aptima showed performance characteristics comparable to those of HPS/CTM and increased sensitivity, making it suitable for use as a clinical diagnostic tool on the fully automated Panther platform.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Plasma / RNA Viral / Monitoramento de Medicamentos / Hepatite C / Hepacivirus / Carga Viral / Soro Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Plasma / RNA Viral / Monitoramento de Medicamentos / Hepatite C / Hepacivirus / Carga Viral / Soro Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article