Your browser doesn't support javascript.
loading
THE EFFECT OF ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION ON THE ASSESSMENT OF DIAGNOSTIC IMAGE QUALITY AND VISUALISATION OF ANATOMICAL STRUCTURES IN PAEDIATRIC CEREBRAL CT EXAMINATIONS.
Larsson, Joel; Båth, Magnus; Ledenius, Kerstin; Thilander-Klang, Anne.
Afiliação
  • Larsson J; Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden Section of Diagnostic Imaging and Functional Medicine, NU Hospital Group, SE-461 85 Trollhättan, Sweden joel.larsson@vgregion.se.
  • Båth M; Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden.
  • Ledenius K; Department of Radiology, Skaraborg Hospital, SE-541 85 Skövde, Sweden.
  • Thilander-Klang A; Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden.
Radiat Prot Dosimetry ; 169(1-4): 115-22, 2016 Jun.
Article em En | MEDLINE | ID: mdl-26873712
The purpose of this study was to investigate the effect of adaptive statistical iterative reconstruction (ASiR) on the visualisation of anatomical structures and diagnostic image quality in paediatric cerebral computed tomography (CT) examinations. Forty paediatric patients undergoing routine cerebral CT were included in the study. The raw data from CT scans were reconstructed into stacks of 5 mm thick axial images at various levels of ASiR. Three paediatric radiologists rated six questions related to the visualisation of anatomical structures and one question on diagnostic image quality, in a blinded randomised visual grading study. The evaluated anatomical structures demonstrated enhanced visibility with increasing level of ASiR, apart from the cerebrospinal fluid space around the brain. In this study, 60 % ASiR was found to be the optimal level of ASiR for paediatric cerebral CT examinations. This shows that the commonly used 30 % ASiR may not always be the optimal level.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encéfalo / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Modelos Estatísticos / Exposição à Radiação Tipo de estudo: Clinical_trials / Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encéfalo / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Modelos Estatísticos / Exposição à Radiação Tipo de estudo: Clinical_trials / Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Ano de publicação: 2016 Tipo de documento: Article