Your browser doesn't support javascript.
loading
Influence of age, sex, body mass index, alcohol, and smoking on shear wave velocity (p-SWE) of the pancreas.
Stumpf, Sabina; Jaeger, Heike; Graeter, Tilmann; Oeztuerk, Suemeyra; Schmidberger, Julian; Haenle, Mark Martin; Kratzer, Wolfgang.
Afiliação
  • Stumpf S; Department of Internal Medicine I, University Hospital Ulm, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
  • Jaeger H; Division of Neurophysiology, FASCIA Research, Albert-Einstein-Allee 11, 89081, Ulm, Germany.
  • Graeter T; Department of Diagnostic and Interventional Radiology, University Hospital Ulm, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
  • Oeztuerk S; Department of Internal Medicine I, University Hospital Ulm, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
  • Schmidberger J; Department of Internal Medicine I, University Hospital Ulm, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
  • Haenle MM; Department of Internal Medicine I, University Hospital Ulm, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
  • Kratzer W; Department of Internal Medicine I, University Hospital Ulm, Albert-Einstein-Allee 23, 89081, Ulm, Germany. Wolfgang.kratzer@uniklinik-ulm.de.
Abdom Radiol (NY) ; 41(7): 1310-6, 2016 07.
Article em En | MEDLINE | ID: mdl-26880176
ABSTRACT

PURPOSE:

A variety of elastographic techniques have been developed to facilitate the non-invasive assessment of tissue properties. The goal of the study was to examine the influence of gender, age, BMI, alcohol consumption, and smoking in healthy volunteers.

METHODS:

Of the 263 participants who met all the study inclusion criteria, 234 had successful measurements. The examination was performed with the Siemens Acuson S3000 (Siemens Healthcare, Erlangen, Germany), using the 6C1 curved array transducer with the virtual touch tissue quantification (VTQ) method.

RESULTS:

The values determined with the curved array in the head of the pancreas were 1.44 ± 0.39 m/s for women and 1.19 ± 0.29 m/s for men; in the body, the results were 1.49 ± 0.37 m/s for women and 1.26 ± 0.30  m/s for men; in the tail, the corresponding values were 1.29 ± 0.36 m/s for women and 1.05 ± 0.30 m/s for men. Comparison of gender showed that men have significantly lower mean values than women. There were significantly higher values in all parts of the organ with the increasing age of the participants (p < 0.0001). For BMI, there was a significant correlation with the values only when considering the BMI in continuous form. Alcohol consumption and smoking did not have any significant effects.

CONCLUSIONS:

ARFI-VTQ is qualified for use on pancreatic tissue. Further studies are required to examine the influence of other factors in larger populations.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pâncreas / Técnicas de Imagem por Elasticidade / Voluntários Saudáveis Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pâncreas / Técnicas de Imagem por Elasticidade / Voluntários Saudáveis Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2016 Tipo de documento: Article