Your browser doesn't support javascript.
loading
Damage Effects on Bacille Calmette-Guérin by Low-Frequency, Low-Intensity Ultrasound: A Pilot Study.
Su, Hang; Li, Zhe; Dong, Yuan; Jiang, He-Xun; Zheng, Hui-Min; Du, Yong-Hong; Wu, Junru; Wang, Zhi-Biao.
Afiliação
  • Su H; State Key Laboratory of Ultrasound Engineering in Medicine, Cofounded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Biomedical Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China (H.S., Z.L., Y.D., H.-Z.J., H.-M.Z, Y.-
  • Li Z; State Key Laboratory of Ultrasound Engineering in Medicine, Cofounded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Biomedical Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China (H.S., Z.L., Y.D., H.-Z.J., H.-M.Z, Y.-
  • Dong Y; State Key Laboratory of Ultrasound Engineering in Medicine, Cofounded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Biomedical Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China (H.S., Z.L., Y.D., H.-Z.J., H.-M.Z, Y.-
  • Jiang HX; State Key Laboratory of Ultrasound Engineering in Medicine, Cofounded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Biomedical Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China (H.S., Z.L., Y.D., H.-Z.J., H.-M.Z, Y.-
  • Zheng HM; State Key Laboratory of Ultrasound Engineering in Medicine, Cofounded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Biomedical Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China (H.S., Z.L., Y.D., H.-Z.J., H.-M.Z, Y.-
  • Du YH; State Key Laboratory of Ultrasound Engineering in Medicine, Cofounded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Biomedical Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China (H.S., Z.L., Y.D., H.-Z.J., H.-M.Z, Y.-
  • Wu J; State Key Laboratory of Ultrasound Engineering in Medicine, Cofounded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Biomedical Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China (H.S., Z.L., Y.D., H.-Z.J., H.-M.Z, Y.-
  • Wang ZB; State Key Laboratory of Ultrasound Engineering in Medicine, Cofounded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Biomedical Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China (H.S., Z.L., Y.D., H.-Z.J., H.-M.Z, Y.-
J Ultrasound Med ; 35(3): 581-7, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26887448
ABSTRACT

OBJECTIVES:

To perform an in vitro experimental study of the possible damage effects on Bacille Calmette-Guérin (BCG) by low-frequency (42-kHz) ultrasound (US) irradiation at low spatially and temporally averaged intensities and different exposure times.

METHODS:

A 2-mL BCG suspension was added to the wells of a 24-well cell culture plate. Then the samples were randomly divided into 4 groups, each group including 3 wells, with group 1 as a control group and groups 2, 3, and 4, as US treatment groups. The samples for groups 2, 3, and 4 were irradiated with US at 0.13 W/cm(2) for 5 minutes, 0.13 W/cm(2) for 15 minutes, and 1.53 W/cm(2) for 15 minutes, respectively. After irradiation, the temperature, ratio of damage, and structure of the bacteria were examined. The cavitation effect of the device was detected by the passive cavitation detection method.

RESULTS:

After US irradiation at the different doses (intensity and exposure time), no significant temperature change was found in all sample suspensions. The ratio of bacterial damage tested by flow cytometry and the optical density of the suspensions as assayed by the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide colorimetric method showed that the US-irradiated groups were significantly different from the control group. The BCG damage ratio reached 28% at the intensity of 1.53 W/cm(2). Transmission electron microscopic results showed that the bacterial structure of BCG could be destroyed by low-frequency, low-intensity US.

CONCLUSIONS:

Low-frequency, low-intensity US can cause acute injury to BCG, and the degree of injury is closely correlated with the US dose applied.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia por Ultrassom / Ondas Ultrassônicas / Mycobacterium bovis Limite: Female / Humans / Male Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia por Ultrassom / Ondas Ultrassônicas / Mycobacterium bovis Limite: Female / Humans / Male Idioma: En Ano de publicação: 2016 Tipo de documento: Article