Dissemination of thermodynamic temperature above the freezing point of silver.
Sadli, M; Machin, G; Anhalt, K; Bourson, F; Briaudeau, S; del Campo, D; Diril, A; Kozlova, O; Lowe, D H; Mantilla Amor, J M; Martin, M J; McEvoy, H C; Ojanen-Saloranta, M; Pehlivan, Ö; Rougié, B; Salim, S G R.
Afiliação
  • Sadli M; High Temperature Metrology Department, Laboratoire Commun de Métrologie, LNE-Cnam, 61 rue du Landy, St Denis 93210, France mohamed.sadli@cnam.fr.
  • Machin G; Engineering Measurement Division, National Physical Laboratory (NPL), Hampton Road, Teddington TW11 0LW, UK.
  • Anhalt K; Physikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, Berlin 10587, Germany.
  • Bourson F; High Temperature Metrology Department, Laboratoire Commun de Métrologie, LNE-Cnam, 61 rue du Landy, St Denis 93210, France.
  • Briaudeau S; High Temperature Metrology Department, Laboratoire Commun de Métrologie, LNE-Cnam, 61 rue du Landy, St Denis 93210, France.
  • del Campo D; Centro Español de Metrologia (CEM), C/del Alfar, 2, Tres Cantos 28760, Spain.
  • Diril A; Tubitak Ulusal Metroloji Enstitüsü (TUBITAK UME), Gebze/Kocaeli 41400, Turkey.
  • Kozlova O; High Temperature Metrology Department, Laboratoire Commun de Métrologie, LNE-Cnam, 61 rue du Landy, St Denis 93210, France.
  • Lowe DH; Engineering Measurement Division, National Physical Laboratory (NPL), Hampton Road, Teddington TW11 0LW, UK.
  • Mantilla Amor JM; Centro Español de Metrologia (CEM), C/del Alfar, 2, Tres Cantos 28760, Spain.
  • Martin MJ; Centro Español de Metrologia (CEM), C/del Alfar, 2, Tres Cantos 28760, Spain.
  • McEvoy HC; Engineering Measurement Division, National Physical Laboratory (NPL), Hampton Road, Teddington TW11 0LW, UK.
  • Ojanen-Saloranta M; Thermal and Mass Metrology, VTT Technical Research Centre of Finland Ltd, Centre for Metrology MIKES, Espoo 02150, Finland.
  • Pehlivan Ö; Tubitak Ulusal Metroloji Enstitüsü (TUBITAK UME), Gebze/Kocaeli 41400, Turkey.
  • Rougié B; High Temperature Metrology Department, Laboratoire Commun de Métrologie, LNE-Cnam, 61 rue du Landy, St Denis 93210, France.
  • Salim SG; High Temperature Metrology Department, Laboratoire Commun de Métrologie, LNE-Cnam, 61 rue du Landy, St Denis 93210, France Radiometry and Photometry Division, National Institute of Standards (NIS), President Sadat Street, El-Haram, PO Box 136, Giza, Egypt.
Philos Trans A Math Phys Eng Sci ; 374(2064): 20150043, 2016 Mar 28.
Article em En | MEDLINE | ID: mdl-26903097
The mise-en-pratique for the definition of the kelvin at high temperatures will formally allow dissemination of thermodynamic temperature either directly or mediated through high-temperature fixed points (HTFPs). In this paper, these two distinct dissemination methods are evaluated, namely source-based and detector-based. This was achieved by performing two distinct dissemination trials: one based on HTFPs, the other based on absolutely calibrated radiation thermometers or filter radiometers. These trials involved six national metrology institutes in Europe in the frame of the European Metrology Research Programme joint project 'Implementing the new kelvin' (InK). The results have shown that both dissemination routes are possible, with similar standard uncertainties of 1-2 K, over the range 1273-2773 K, showing that, depending on the facilities available in the laboratory, it will soon be possible to disseminate thermodynamic temperatures above 1273 K to users by either of the two methods with uncertainties comparable to the current temperature scale.