For avid glucose tumors, the SUV peak is the most reliable parameter for [(18)F]FDG-PET/CT quantification, regardless of acquisition time.
Sher, Avigaëlle; Lacoeuille, Franck; Fosse, Pacôme; Vervueren, Laurent; Cahouet-Vannier, Aurélie; Dabli, Djamel; Bouchet, Francis; Couturier, Olivier.
Afiliação
  • Sher A; Nuclear Medicine Department, University Hospital - Angers, 4 rue Larrey 49933, Angers, Cedex 09, France. av.sher@yahoo.com.
  • Lacoeuille F; Nuclear Medicine Department, University Hospital - Angers, 4 rue Larrey 49933, Angers, Cedex 09, France.
  • Fosse P; LUNAM Université - INSERM UMR-S 1066, Micro et nanomédecine biomimétiques, 4 rue Larrey 49933, Angers, Cedex 09, France.
  • Vervueren L; Nuclear Medicine Department, University Hospital - Angers, 4 rue Larrey 49933, Angers, Cedex 09, France.
  • Cahouet-Vannier A; Nuclear Medicine Department, University Hospital - Angers, 4 rue Larrey 49933, Angers, Cedex 09, France.
  • Bouchet F; Nuclear Medicine Department, University Hospital - Angers, 4 rue Larrey 49933, Angers, Cedex 09, France.
  • Couturier O; Nuclear Medicine Department, University Hospital - Angers, 4 rue Larrey 49933, Angers, Cedex 09, France.
EJNMMI Res ; 6(1): 21, 2016 Dec.
Article em En | MEDLINE | ID: mdl-26944734
ABSTRACT

BACKGROUND:

This study is an assessment of the impact of acquisition times on SUV with [(18)F]FDG-PET/CT on healthy livers (reference organ with stable uptake over time) and on tumors.

METHODS:

One hundred six [(18)F]FDG-PET/CT were acquired in list mode over a single-bed position (livers (n = 48) or on tumors (n = 58)). Six independent datasets of different durations were reconstructed (from 1.5 to 10 min). SUVmax (hottest voxel), SUVpeak (maximum average SUV within a 1-cm(3) spherical volume), and SUVaverage were measured within a 3-cm-diameter volume of interest (VOI) in the right lobe of the liver. For [(18)F]FDG avid tumors (SUVmax ≥ 5), the SUVmax, SUVpeak, and SUV41% (isocontour threshold method) were computed.

RESULTS:

For tumors, SUVpeak values did not vary with acquisition time. SUVmax displayed significant differences between 1.5- and 5-10-min reconstruction times. SUV41% was the most time-dependent parameter. For the liver, the SUVaverage was the sole parameter that did not vary over time.

CONCLUSIONS:

For [(18)F]FDG avid tumors, with short acquisition times, i.e., with new generations of PET systems, the SUVpeak may be more robust than the SUVmax. The SUVaverage over a 3-cm-diameter VOI in the right lobe of the liver appears to be a good method for a robust and reproducible assessment of the hepatic metabolism.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article